SCHUNK Motion protocol
05/STM-48V/en/2011-04-01/CW
61
Miscellaneous:
Spontaneous response when position reached
or in case of prior termination of positioning.
D-Len
Cmd
Param
Meaning
M ► S
0x05
0xB0
0x00 0x00 0x20 0x41
Move to position 10.0[mm]
S ► M
0x05
0xB0
0xCD 0xCC 0x04 0x41
Will reach position in 8.3[sec]
Table 27 Example for MOVE POS
Command Code:
0xB3
Description:
A current move is executed.
Parameters
(Master ► Slave)
:
Current in configured unit system (must be specified).
Response
(Slave ► Master)
:
"OK" (0x4F4B) if successful. The
module executes the command.
Miscellaneous:
Spontaneous message is possible.
D-Len
Cmd
Param
Meaning
M ► S
0x05
0xB3
0x00 0x00 0x60 0x40
Execute current move with 3.5[A]
S ► M
0x05
0xB3
0x4F 0x4B
Table 28 Example for MOVE CUR
Command Code:
0xB5
Description:
A velocity move is executed.
Parameters
(Master ► Slave)
:
•
Velocity in configured unit system (must be specified)
•
Current (optional)
Response
(Slave ► Master)
:
"OK" (0x4F4B) if successful. The
module executes the command.
Miscellaneous:
Spontaneous message is possible if the module
is no longer moving.
D-Len
Cmd
Param
Meaning
M ► S
0x05
0xB5
0x9A 0x99 0x31 0x41
Execute velocity move with
11.1[mm/s]
S ► M
0x05
0xB5
0x4F 0x4B
Table 29 Example for MOVE VEL
Current move