Assembly and settings
24
04.00 | RST-D | Assembly and Operating Manual | en | 389517
5.3.5 Setting the end position dampers
The dampers are factory-set so that the product can be operated
safely with the maximum permissible load.
With smaller loads, an adjustment may be necessary to achieve
the optimal cycle times through withdrawing the dampers.
CW
ACW
Setting the end position dampers
NOTE
Dampers (57) do not serve as an end stop for the drive, but only
for dampening.
The drive piston must reach the intended stops, otherwise the
module cannot lock correctly and continue pulsing.
• Always set the dampers (57) back so that the product performs
the full angle stroke and allows pulsing to continue. The angle
stroke and the cycling are engraved onto the middle section.
The dampers need to be set for the respective load-swivel
direction.
Swivel direction
Dampers
Anti-clockwise (ACW)
A
Clockwise (CW)
B