Assembly and settings
04.00 | RST-D | Assembly and Operating Manual | en | 389517
17
5 Assembly and settings
5.1 Assembling and connecting
WARNING
Risk of injury due to unexpected movements!
If the power supply is switched on or residual energy remains in
the system, components can move unexpectedly and cause
serious injuries.
•
Before starting any work on the product: Switch off the power
supply and secure against restarting.
•
Make sure, that no residual energy remains in the system.
WARNING
Risk of injury from the procuct falling during assembly and
operation !
•
Make sure that the product is securely mounted on the
machine/system
NOTICE
Material damage due to improper assembly!
•
When mounting loads, do not allow impermissible forces and
moments to be exerted (see catalog data sheet).
•
Select a suitable tightening torque when assembling the
product or loads on the product in accordance with the
generally accepted guidelines for screw connections.
•
Secure all screws using a suitable chemical screw lock.
NOTICE
Damage to the rotary module possible!
The rotary module can be damaged if it arrives too abruptly in
the end position.
•
The rotary motion must reach the end position without jerk or
bounce.
•
Therefore flow control valves and shock absorbers must be
used,
•
Please observe the information in the catalog pages.
NOTE
Observe the requirements for the compressed air supply,