Maintenance
32
04.00|ROTA FSW |en
Maintenance
To comply with the radial and axial run-out tolerances, the
corresponding back stop and guide diameter must be clean.
Compliance with the maintenance, cleaning and replacement
intervals of the flexible adapter is essential.
NOTICE
Risk of damage to the adapter due to cleaning with compressed
air.
When cleaning the adapter with compressed air, metal chips can
become trapped in the threads and grooves. That can damage or
even destroy the adapter.
Lubrication
To maintain the safe function and high quality of the chuck quick-
change ROTA FSW, it has to be regularly lubricated.
A
Lubrication nipples on the circumference
Turn the chuck quick-change into the open position. Lubricate the
chuck at the lubrication nipples (A) using a high-pressure grease
gun with 2 - 4 strokes (depending on the chuck side) of SCHUNK
LINO MAX special grease.
For optimum grease distribution, the chuck quick-change must be
closed and opened several times after lubrication.
8
8.1