Mounting
04.00|ROTA FSW |en
19
Mounting
Installing and connecting
WARNING
Risk of injury due to unexpected movements!
If the power supply is switched on or residual energy remains in
the system, components can move unexpectedly and cause seri-
ous injuries.
• Before starting any work on the product: Switch off the power
supply and secure against restarting.
• Ensure that no residual energy remains in the system.
CAUTION
Danger of injury due to sharp edges and rough or slippery sur-
faces
• Wear personal protective equipment, particularly protective
gloves.
1 Checking the holder of the ROTA FSW or the intermediate
flange
2 Assembly of the ROTA FSW chuck quick-change
3 Performing a functional check
Checking the spindle nose for mounting the chuck quick-
change
For high run-out accuracy of the ROTA FSW chuck quick-change or
the substituted-in clamping device, the machine side must be
aligned before assembly of the ROTA FSW chuck quick-change or
the intermediate flange. To do this, check the contact surfaces on
the spindle for axial and concentric run-out using a dial indicator
(see Fig. "Assembly of the chuck quick-change or intermediate
flange" - A).
There should be a maximum concentricity error in the centering
of the mount of 0.005 mm and a maximum axial run-out error in
the contact surfaces of 0.005 mm. The flat surface of the spindle
must also be checked for flatness using a straight edge.
Make sure that the surface area of the flat surface is chamfered at
the bore holes and is clean.