Maintenance
36
02.00|PZH-plus 020-075|en
Disassembly of the module
Position of the position numbers
Assembly tools are needed for disassembly
WARNING
Risk of injury from uncontrolled movements!
If the energy supply is switched on or residual energy remains in the
system, parts may move unexpectedly and cause serious injuries.
• Switch off energy supply.
• Make sure there is no residual energy in the system
1
Close the gripper and remove the compressed air lines.
2 Remove the cover (15) and unclamp the eccentric (9). To do this,
rotate the eccentric (9) by 90° to the left. Marking has to show in
the direction of the outside wall.
3 Remove the nuts (61).
4 Remove the set-screw (45) and undo the screws (46) though the
base plate (13).
5 Remove the base plate (13).
6 Remove the toothed belt (11).
7 Remove the toothed belt (20).
8 Remove the bearings (20 / 21), fitting disks (39) and the
eccentric (9).
9 Base jaw clamping piece (10) and centering sleeves (62).
10 Remove the base jaw (4).
7.4