Assembly
28
08.00 | PZB-plus | Assembly and Operating Manual | en | 389366
5.3.6 Mounting MMS 22-PI1 programmable magnetic switch
CAUTION
Risk of damage to the sensor during assembly!
•
Observe the maximal tightening torque.
NOTE
If there is no T-nut available, slide the sensor according to
dimension I1 into the groove (2),
Size 50 – 160
Ø
Turn the sensor 1 (1) into the groove (2).
OR: Slide the sensor 1 (1) into the groove (2) until the
sensor 1 (1) stops at the T-nut (3).
Ø
Secure the sensor 1 (1) using the set-screw (4).
Tightening torque: 10 Ncm
Ø
Adjust sensor 1 (1), see sensor assembly and operating manual.
Ø
Repeat steps for sensor 2.
Size 200 – 300
Ø
Bring gripper in the position in which it is to be set.
Ø
Hold teaching tool to the sensor 1 (1) until the sensor flashes.
Ø
Slide sensor 1 (1) into the groove (2), until the sensor 1 flashes
rapidly.
✓
The optimal position is displayed.
Ø
Secure the sensor 1 (1) using the set-screw (4).
Tightening torque: 10 Ncm
Ø
Hold teaching tool to the sensor 1 (1), to confirm the position.
✓
The sensor 1 (1) has been taught in.
Ø
Repeat steps for sensor 2.