5.2.3 Mounting the magnetic switch MMS 22
CAUTION
Risk of damage to the sensor during assembly!
•
Observe the maximal tightening torque.
Positioning the
magnetic switch
2
3
1
4
Position "Gripper open":
Ø
Put the product in the desired position.
Ø
Push the sensor 1 (1) into the groove (4) until it stops at the
housing.
Ø
Pull the sensor 1 (1) back again slowly until it switches.
Ø
Secure the sensor 1 (1) in this position using the set screw (3).
✓
Max. tightening torque: 10 Ncm
Ø
Put product into the "gripper open" position and test the
function.
Position "Gripper closed" or "Part gripped (O.D. gripping)":
Ø
Put the product in the desired position.
Ø
Push the sensor 2 (2) into the groove (4) towards the middle of
the gripper until it switches.
Ø
Secure the sensor 2 (2) in this position using the set screw (3).
✓
Max. tightening torque: 10 Ncm
Ø
Put product into the "gripper closed" or "part gripped (O.D.
gripping)" position and test the function.