![SCHUNK PGN-plus-P Assembly And Operating Manual Download Page 20](http://html1.mh-extra.com/html/schunk/pgn-plus-p/pgn-plus-p_assembly-and-operating-manual_1215988020.webp)
Assembly
20
10.00 | PGN-plus-P | Assembly- and Operating Manual | en | 389753
Dust-tight (SD)
NOTE
In order to achieve perfect functioning of the gripper, the set-
screw of the air purge connection must be removed and replaced
with a pneumatic connection when using the dust-tight variant
(SD). SCHUNK recommends using the air purge connection within
the scope of the technical data,
5.2 Connections
5.2.1 Mechanical connection
Evenness of the
mounting surface
The values apply to the whole mounting surface to which the
product is mounted.
Requirements for evenness of the mounting surface (Dimensions in mm)
Edge length
Permissible unevenness
< 100
< 0.02
> 100
< 0.05
Connections at the
base jaws
Connections at the base jaws
Item Mounting
PGN-plus-P
40
50
64
80
100 125
1
Centering sleeve
Ø4
Ø5
Ø6
Ø8 Ø10 Ø10
2
Thread in base jaws
M2.
5
M3 M4 M5 M6 M6
Mounting screw strength
class
12.9
Max. depth of engagement
from locating surface [mm]
6.1
8.5 10.7 11.9 14.2 14.2