Assembly
6.2.4 LE100 incremental measuring system
Description
LE100
Operating voltage [VDC]
5 ± 5 %
Output signal
Sin, Cos
Signal amplitude [Vss]
1 ± 10 %
Offset sine/cosine [V]
2.5 ± 0.5 %
Signal period [µm]
1000
Reference signal, periodic [mm]
20
Distance, reading head – measuring tape
[mm]
0.05 - 0.2
Pin
Assignment
1
N.C.
2
SIN+
3
SIN-
4
GND
5
COS+
6
COS-
7
N.C.
8
N.C.
9
REF+
10
REF-
11
N.C.
12
Vcc
13
N.C.
14
N.C.
15
0V Sense
89
06.00 | LDL | Assembly and Operation Manual | en | GAS341441