Technical data
12
01.00|HGN |en
Technical data
Nominal working pressure [bar]
45
Pressure medium
hydraulic oil, filtered (10 microns),
viscosity 46 mm
2
/s at 40°C
in accordance with ISO VG
Min. pressure [bar]
30
Max. pressure [bar]
45
Noise emission [dB(A)]
≤ 70
max. admissible volume of current [l/min]
2
Max. oil leakaget [mg/Zyklus]
0.5
NOTE
Don’t fall below the min. closing-/ and opening times
Designation
HGN
80
80 AS
100
100 AS 125 125 AS 160 160 AS
Closing time [s]
0.15
0.15
0.2
0.2
0.3
0.4
Opening time [s]
0.15
0.2
0.2
0.3
0.3
0.4
Further technical data can be found in the catalog data sheet.
The most recent version applies.