Technical data
16
02.00 | FT-AXIA | Assembly and Operating Manual | en | 1517831
3.2 Ambient conditions and operating conditions
Designation
FT-AXIA
80
90
130
Storage temperature [°C]
Min.
Max.
-20
+85
-45
+85
Operating temperature [°C]
Min.
Max.
0
+65
-20
+70
Relative air humidity [%]
<95, non-condensing
IP rating
64
67
The catalog data sheet contains more information.
3.3 Standard peak values
NOTE
When switched on, the sensor records the peak values loaded on
each individual axis. The following values are the factory default
values programmed during calibration. If the sensor displays peak
values that are higher than these default values, the sensor has
been loaded beyond the intended calibrated detection range.
Designation
Fxy [N]
Fz [N]
Mxy [Nm]
FT-AXIA80-DUAL SI-75-4/SI-150-8
Positive default
value
2.25 x 10
8
7.05 x 10
8
1.2 x 10
7
Negative
default value
-2.25 x 10
8
-7.05 x 10
8
-1.2 x 10
7
FT-AXIA80-DUAL SI-200-8/SI-500-20
Positive default
value
7.5 x 10
8
1.35 x 10
9
3.0 x 10
7
Negative
default value
-7.5 x 10
8
-1.35 x 10
9
-3.0 x 10
7
FT-AXIA80-DUAL SI-480-20/SI-1200-50
Positive default
value
7.499988 x 10
8
1.249998 x 10
9
3.123995 x 10
7
Negative
default value
-7.499988 x 10
8
-1.249998 x 10
9
-3.123995 x 10
7
FT-AXIA90-SI-1000-50
Positive default
value
6.24999 x 10
8
1.249998 x 10
9
3.124995 x 10
7
Negative
default value
-6.24999 x 10
8
-1.249998 x 10
9
-3.124995 x 10
7