Technical data
24
05.01|EVG 55|en
Motor data
Reference value
EVG 55
Stroke 40
EVG 55
Hub 100
Terminal voltage U
kl
[V]
24
Torque constant K
t
[Ncm/A]
1.3
3.8
Ambient temperature
θ
u
[°C]
40
Maximal winding temperature
θ
max
[°C]
140
Thermal transfer resistance R
th
[K/W]
4.5
3.25
Maximal torque M
max
[Ncm]
23.5
72.4
Maximal current I
max
[Aeff]
16.0
Permanent standstill torque M
o
[Ncm]
5.9
18.0
Permanent standstill current
o
[Aeff]
4.0
3.9
Idle speed n
o
[min-1]
19100
6200
Nominal torque M
n
[Ncm]
5.0
16.3
Nominal current I
n
[Aeff]
3.6
3.7
Nominal torque n
n
[min-1]
15900
5100
Terminal inductance R
tt
[Ω]
0.5 ±7%
0.6 ±7%
Terminal inductance L
tt
[mH]
0.4 ±20%
Electrical time constant
τ
e
[ms]
0.4 ±27%
0.7 ±27%
The tolerances of M, l, n may be around 10%. All temperatures corre-
spond to isolation class F.
Mmax is limited by the maximal current.
3.3