Technical data
20
04.00 - FW 2.x | EGL | Assembly and Operating Manual | en | 389661
3 Technical data
3.1 Basic data
Mechanical operating data
Weight [kg]
1.8
Noise emission [dB(A)]
≤ 70
IP rating*
46
Ambient temperature [°C]
Min.
Max.
5
55
Brake
Brake
available **
Internal motor operating data
Motor current at nominal gripping force [A]
4.25
Internal logic supply fuse ***
Value [A]
Tripping characteristic
1
time delay
Power supply
Logic voltage supply [VDC]
24 ± 10%
Voltage supply output [VDC]
(stabilized and smoothed, internal reverse polarity
protection)
maximum current input (logic) [A]
maximum current input (power) of power supply
unit [A]
24 ± 10%
0.5
2.5
Interface
PROFIBUS [12 MBit/s]
CAN bus [up to 1 MBit/s]
USB Mini AB, device, parameterization interface
USB Micro AB, host
X
X
X
X
IMPORTANT! A product is supplied either with PROFINET or CAN bus.
* For use in dirty ambient conditions (e.g. sprayed water, vapors,
abrasion or processing dust) SCHUNK offers corresponding
product options as standard. SCHUNK also offers customized
solutions for special applications in dirty ambient conditions.
** The built-in, electric holding break is used for mounting and
holding the position of the gripper jaws in the event of a
power failure. It cannot cover all of the safety or gripping force
maintenance functions.
***
SCHUNK recommends: Littelfuse 1A time delay (0154001 .DRTL)
More technical data is included in the catalog data sheet.
Whichever is the latest version.