Maintenance
48
28.00 | DPG-plus | Assembly and Operating Manual | en | 389031
7.6 Disassembly and assembly
7.6.1 Version without gripping force maintenance
Position of the item numbers:
•
Previous version:
Assembly drawing (previous version)
•
Successor version:
Assembly drawing (successor version)
Disassembling
Ø
Remove the compressed air hose.
Ø
Unfasten and remove the screws (47).
Ø
Previous version:
Remove the cover (5) and seal (37/20).
Successor version:
Remove the cover (5) and flat seal (20).
Ø
Mark the installation positions of the base jaw (2/7) and the
side cover (12) on the housing (1).
Ø
Previous version:
Unscrew screws (42). Remove the side
cover (12) and the gasket (14).
For DPG-plus 240 / 300: Remove O-ring (39).
Successor version:
Unscrew and remove screws (42), remove
the side cover (12) and the flat seal ring (39).
IMPORTANT! Do not disassemble the filler piece (18) for
maintenance purposes, as the product may leak. If the filler
piece (18) is nevertheless disassembled, seal the filler piece
(18) with liquid sealant on reassembly.
Ø
Unscrew and remove the screws (41) and remove the cover (4).
Ø
Previous version:
Mark the installation position between the
cylinder piston (60) and the housing (1).
Successor version:
Mark the installation position between the
cylinder piston (71) and the housing (1).
Ø
Unscrew screw (40) and remove cylinder piston (60) from the
housing (1).
Ø
Push the pistons (3/8) upwards out of the housing (1).
NOTE
Do not disassemble the intermediate jaw (13) from the base jaw
(2/7).
Ø
Pull the base jaws (2/7) out of the housing (1).
Ø
Loosen the screw (43) and disassemble the intermediate
jaw (13) from the base jaw (2/7).