Assembly
28.00 | DPG-plus | Assembly and Operating Manual | en | 389031
37
5.4.5 Mounting programmable magnetic switch MMS 22-PI1
CAUTION
Risk of damage to the sensor during assembly!
•
Observe the maximal tightening torque.
NOTE
The magnetic switch MMS 22-PI1 can be adjusted and taught in
two ways.
• "Standard mode" allows for quick installation on the T-nut
preset by SCHUNK in the groove or the defined setting
dimension "l1."
• In "Optimal Mode", the sensor identifies the optimal position in
the groove itself.
SCHUNK recommends "Optimal Mode" for setting the sensors.
Setting the sensor in "Optimum mode"
Ø
Put product in the position in which it is to be set.
Ø
Hold teaching tool to the sensor 1 (1) until the sensor flashes.
Ø
Slide sensor 1 (1) into the groove (2), until the sensor 1 flashes
rapidly.
✓
The optimum position is displayed.
Ø
Secure the sensor 1 (1) using the set-screw (4).
Tightening torque: 10 Ncm
Ø
Hold teaching tool to the sensor 1 (1) to confirm the position.
✓
The sensor 1 (1) has been taught in.
Ø
Repeat steps for sensor 2.