Assembly and Settings
20
03.00 | CLM | Assembly and operating manual | en | 389015
4.3.2 End positions - Sets CLM 10 – 25
The following components are available for stroke limiting, shock
absorption and monitoring of the end positions:
• Stop screw LMAS (option)
• Shock absorbers (included in the scope of delivery)
• Damping adjustment (included in the scope of delivery)
• Sensors (option)
Subsequent the installation of the end position damping is shown.
shock absorber
clamping adjustment
protection
clamping-
screw
shock absorber
stroke
Linear module end positions - Set CLM 10 – 25
Linear module
Damping
adjustment
range Z
[mm]
min. distance X
[mm]
min. distance Y
[mm]
CLM 10
0...2
3.4
3.0
CLM 25
0...1.3
8
13
CAUTION
Material damage due to erroneous settings!
•
Do not fall below minimum distances X and Y.
•
The end stop is the respective shock absorber on both sides;
the inside of the product must not hit the end stop.
Stroke adjustment/
sensor adjustment
Ø
Loosen the attachment screw.
Ø
For CLM 10: Loosen counter nut.
Ø
Set shock absorber and proximity switch IN to the desired
stroke.
IMPORTANT! Do not fall below minimum distances X
and Y.
Ø