USING THE LED LIGHT

Choose from Normal, SOS and Emergency Flash modes.

1.  Press the   button on the side of the unit for 2 seconds to turn on the LED light. The icon   will show on the LCD screen.

2.  Press the   button again for SOS mode.

3.  Press the   button once more for emergency flashing.

4.  Long press the   button for 2 seconds to turn off the LED light.
USING THE AC POWER OUTLETS

The SL1466 is equipped with a 500W pure sine wave inverter, which produces power for all electronic devices and appliances.

It is important to know the continuous wattage of the device you plan to use with the AC outlets. The unit must be used with devices drawing 500 watts or less. 

Devices such as fans or electric motors require additional power to start (commonly known as the “starting” or “peak” power). The generator can supply a momentary surge 

in wattage of as high as 1000W for less than 1/10 of a second; however even devices rated less than the maximum 500 watts can exceed the inverter’s surge capability 

and cause an automatic overload shutdown.

Do not use the inverter with a product that draws a higher wattage than the inverter can provide, as this may cause erratic operation.

CAUTION: Always run a test to establish whether the inverter will operate a particular piece of equipment or device.

In the event of a power overload (noted with a flashing   Warning icon), the inverter is designed to automatically shut down. This safety feature prevents damaging the 

inverter while testing devices and equipment within the 500-watt range.

If powering more than one device, start one device at a time to avoid a power surge and/or inverter overload. The surge load of each device should not exceed the 

inverter’s Continuous Operation wattage rate.

You can use an extension cord from the inverter to the device without significantly decreasing the power being generated by the inverter. For best operating results, the 

extension cord should be 16 AWG (1.31 mm

2

) or larger and no longer than 50 feet.

WARNING! RISK OF ELECTRIC SHOCK. 

Incorrect operation of your inverter may result in damage and personal injury. The inverter output is 110V AC and can shock or electrocute the same as any ordinary 

household AC wall outlet.
NOTE: The maximum continuous load is 500 watts. Do not use the AC outlets with a product that draws more than 500 watts, as this may cause erratic operation. 
CAUTION:

•  Do not connect an AC power source to the 110V AC outlets.

•  Do not connect the unit’s AC power cord to its 110V AC outlets.

NOTE: Do not power an AC device while charging the internal battery. 

1.  Connect your AC-powered devices or small household appliances to one or more of the unit’s two AC outlets. 

NOTE: Make sure the device to be powered is OFF before inserting the plug into the AC power outlet.

2.  Press the AC Power button. The   AC Output icon will show on the display, to confirm that the unit is on and ready to provide AC power. The   Power Output indicator 

will also show on the display.

NOTE: Extended operation of an AC device may result in excessive battery drain. 

3.  Recharge the unit when the battery level is below 40%.
ESTIMATED RUN-TIMES 

APPLIANCE TYPE

ESTIMATED RUN TIME

CHARGES

Jig Saw

2.4 hours

Projector

7 hours

12V Heated blanket

13 hours

12V Cooler

15 hours

Mini Fridge

20 hours

Television

21 hours

Drone

22 hours

103

Fan

26 hours

Router

54 hours

Table lamp

59 hours

Laptop

106 hours

12

LED lights

150 hours

Camera

190 hours

99

Radio

222 hours

Tablet

247 hours

15

Speaker

680 hours

44

Smartphone

765 hours

49

NOTE: Actual time may vary. Times are based on the internal battery being fully charged.

7.  MAINTENANCE AND CARE

• Recharge the unit when the battery level is below 40%.

• Never completely discharge the internal battery. 

Summary of Contents for SL1466

Page 1: ...nd follow these instructions and precautions carefully POR FAVOR CONSERVE ESTE MANUAL DEL USUARIO Y LEALO ANTES DE CADA USO En este manual le explica c mo utilizar la unidad de manera segura y confiab...

Page 2: ...RUCCIONES DE MONTAJE 7 CARACTER STICAS 7 PANTALLA LCD 8 INSTRUCCIONES DE OPERACI N 8 MANTENIMIENTO Y CUIDADO 9 ADVERTENCIAS 10 LOCALIZACI N Y SOLUCI N DE PROBLEMAS 10 ESPECIFICACIONES 10 REPUESTOS 11...

Page 3: ...must have proper ventilation Ensure at least 3 in 7 5 cm air space is maintained on all sides of the unit 1 13 Do not set the unit on flammable materials such as carpeting upholstery paper cardboard...

Page 4: ...input port of the unit Charging will start automatically and the Charging and the Battery Capacity indicators will flash 4 When the internal battery is fully charged all five bars of the Battery Capac...

Page 5: ...on cord from the inverter to the device without significantly decreasing the power being generated by the inverter For best operating results the extension cord should be 16 AWG 1 31 mm2 or larger and...

Page 6: ...If problem persists replace the charger Solar panel charging fault Over current Weak sunlight Damaged solar panel Abnormal wiring harness connection Use only the recommended solar panel Charge in a s...

Page 7: ...reducir el riesgo de descarga el ctrica desenchufe la unidad del tomacorriente antes de intentar llevar a cabo cualquier actividad de mantenimiento o limpieza El simple apagado de los controles no red...

Page 8: ...n los indicadores de carga y de capacidad de la bater a 4 Cuando la bater a interna est totalmente cargada aparecer n en la pantalla las cinco barras del indicador de capacidad de la bater a Despu s...

Page 9: ...nversor al dispositivo sin disminuir significativamente la potencia que genera el inversor Para los mejores resultados de operaci n el cable alargador deber a ser de 16 AWG 1 31 mm2 o mayor y no tener...

Page 10: ...ga an mala Unidad da ada Recargue la unidad Retire las cargas y recargue la unidad Consulte al Servicio al Cliente Falla del cargador Cargador no correspondiente Cargador da ado Fuente de alimentaci n...

Page 11: ...com para obtener piezas de repuesto 13 GARANT A LIMITADA Para obtener informaci n sobre nuestra garant a limitada de un a o visite batterychargers com o llame al 1 800 621 5485 para solicitar una copi...

Page 12: ...icien de r paration 1 10 Ne pas ouvrir l unit Si une r paration est requise communiquez avec le service la client le pour directives 1 11 Pour viter le danger de choc lectrique d branchez l unit de la...

Page 13: ...era automatiquement et les indicateurs de chargement et de capacit de r serve des piles se mettront clignoter 4 Lorsque les piles internes seront compl tement recharg es les cinq barres de l indicateu...

Page 14: ...s s le cordon de rallonge devrait tre de calibre n 16 AWG 1 31 mm2 ou de section plus grande et de longueur inf rieure 15 m 50 pi AVERTISSEMENT DANGER DE CHOC LECTRIQUE L utilisation anormale de votre...

Page 15: ...OLUTION D faillance la mise sous tension Protection de basse tension Protection de charge anormale Unit endommag e Recharger l unit Retirer les charges et recharger l unit Contacter le service la clie...

Page 16: ...CHANGE Chargeur CA 930261007Z 12 AVANT DE RETOURNER POUR LES R PARATIONS Pour R PARATION OU RETOUR visitez 365rma com Aller sur batterychargers com pour les pi ces de rechange 13 GARANTIE LIMIT E Pour...

Reviews: