Schulze AirPress4 Use Instructions Download Page 1

TECHNICAL DATA

dimension in ca:

160 x 160 x 200

weight inclusive cabinet

160kg

operation current

230volts

electrical performance

2,5kw

airconsumption per operation cycle

3,3L

pressure performance at 6bar

2490kg

max. pressure

6bar

temperatur range<.

0 - 220°C

adjustable operation time:

0 - 9´ 59”

max. variations of temperature at 180°C
(measured inside the heat plate)

-1/+3°C

Pneumatical Press with 4 working platen

heat platen dimensions:

40 x 50cm

base platen:

4pieces 40 x 50cm

Interchangeable heat platen:
20 x 20cm
38 x 45cm
40 x 50cm

USE INSTRUCTIONS

display

pressure display

temperature and time adjustor

pressure switch OFF

pressure switch ON

Plugin for cooling pump max. 2amp

compressed air adatper

power connection cable

main switch

fuse 12amp

emergency OFF switch

working plate

(base plate)

power cord of the heat plate

fastening screw of the

heat plate

heat plate

4

cooling pump

cooling plate

1

Summary of Contents for AirPress4

Page 1: ...e heat plate 1 3 C Pneumatical Press with 4 working platen heat platen dimensions 40 x 50cm base platen 4pieces 40 x 50cm Interchangeable heat platen 20 x 20cm 38 x 45cm 40 x 50cm USE INSTRUCTIONS dis...

Page 2: ...ol Cleaning Air pressure and power have to be disconnected before commencing any service work Pull out the plug additionally For replacing interchange of any platen please wait until the installed pla...

Page 3: ...PRESS PRE PRESSING Vor opening the press before finishing the adjusted working cycle please press both yellow OFF keys at once and keep them down until the heatplate stopped at its top position Then t...

Page 4: ...0 C 12VDC K F S1 S CRYDOM Time OFF 12V Thermoregulator timer S10 Hauptschalter Wlacznik gl wny Main switch S1 Time start czarny schwarz black S4 Setup zolty gelb yellow S5 Temperature zielony gr n gre...

Page 5: ...ch Activates the control above the work plate only Moving of the heat plate Micro switch 5 blue niebieski red czerwony red czerwony red czerwony 230VAC 12V 12V Power supply unit Zasilacz 10 13 blue ni...

Page 6: ...Open up the water valve for filling up the unit 5 6 7 8 Fill up the cooling unit by a water hose or a funnel until it overflows the de ventilation valves Close the lower valve and drain the water hos...

Page 7: ...ing EG rules for machines 89 37 EC Die Walter Schulze GmbH Schmalenbachstr 15 D 12057 Berlin Declares herewith as European authorized agent for the manufacturer firm Romanik that the following describ...

Reviews: