background image

Instructions for use.

hts.

 The universal hygiene system. 

hts.

Summary of Contents for rifton hts

Page 1: ...Instructions for use hts The universal hygiene system hts...

Page 2: ...for use carefully prior to initial commissioning of the product and to observe them Please note that gui delines and representations in these Instructions for use may deviate from your product due to...

Page 3: ...h the intended purpose warning gui delines 07 2 5 Equipment for basic model 08 2 6 List of accessories 08 2 7 Product overview 09 3 Settings 09 3 1 Back angle adjustment 10 3 2 Armrest existence 10 3...

Page 4: ...5 1 2 Disinfection 23 5 2 Servicing 24 5 3 Maintenance 24 5 3 1 Maintenance specifications 24 5 3 2 Maintenance plan 25 5 4 Spare parts 25 5 5 Duration of use and re use 25 6 Technical data 26 7 Guara...

Page 5: ...eserve and protect the environment to prevent environmental pollution and to improve the recycling of raw materials please note the disposal instructions in points 1 3 1 and 1 3 2 1 3 1 Packaging The...

Page 6: ...st compact size fold up foot support seat depth to lowest setting etc 2 3 Application areas use according to the intended purpose The hts shower and toilet chair is a medical product of risk class 1 a...

Page 7: ...airment of the torso control 2 3 3 Contraindications In general the indication should be accompanied by a doctor ortho paedist It should therefore be clarified prior to procurement whether contraindic...

Page 8: ...g must have someone read these In structions for use aloud so that they understand how to use the product 2 5 Equipment for basic model Seat unit incl pelvis strap and removable armrests Adjustable se...

Page 9: ...show you the designation of the most important components as well as the terms which you will find in these Instructions for use Settings and adjustments to the product or accessories may only be mad...

Page 10: ...ce it back in the mount so that the F G markings are on top of each other again Then pull the back towards the rear until it clicks into the first setting Only assemble disassemble the back when not i...

Page 11: ...he transfer and care sub frame can be adjusted in height In order to adjust the height of the transfer and care sub frame press down the foot pedal D on the left or right hand side of the sub frame wi...

Page 12: ...adjustment do not need to be released The height may only be adjusted when not in use The seat tilt can be adjusted for the mobile sub frames Press the adjust ment lever C on the right rear side of th...

Page 13: ...re attaching the seat Subsequently attach the toilet seat to the frame see Point 4 1 The travel sub frame cannot be used for size 3 4 2 Pads All pads can be removed for cleaning Pull the press fasten...

Page 14: ...otte pads are availa ble with or without chest strap and ensure safe positioning of the up per body Using the twist lever D behind the backrest they can be adjusted separately in height angle and widt...

Page 15: ...der to ensure the safe sitting positi on of smaller active users the hts size 1 also offers the additional possibility to attach a pelvic strap Guide the belt through the hooks at the rear of the seat...

Page 16: ...rap B with the inte grated pelvic strap Tighten the pelvic strap and insert the shoulder straps into the brackets on the backrest You can also pull the shoulder straps th rough the upper opening in th...

Page 17: ...y 10 cm in the second position Slide the thigh guides into the armrest so that the inlet A in the thigh guides point up and to the back Insert the armrest B through the thigh guides into the recess fo...

Page 18: ...he little metal brackets A on the ends of the frame B into the recess C on the back of the seat unit 2 Firmly press the foot support down so that the frame audibly clicks into the blue brackets D 3 At...

Page 19: ...spor ting at ground level 4 10 Calf guide The calf guide C is mounted above the foot support D It should be re moved if the foot support is set to one of the top positions The calf guide is attached o...

Page 20: ...washed at 30 C Seal the hook and loop before washing Do not iron This option requires the use of a foot support C A A B D 4 12 Table arm support The table has a padded extensive stomach support area o...

Page 21: ...ackets D of the attachment bars see Point 4 1 and lower the seat onto the toilet bowl In order to avoid falls and injuries ensure that the toilet is connected firmly to the ground and that the retaine...

Page 22: ...them with a soapy solution or a mild disinfectant 4 16 Deflector The standard deflector A is inserted into the seat pad opening with the hollow side facing the user The deflector with splash guard B...

Page 23: ...y attention to the sewn in care labels such as A B on the respective element Please also pay atten tion to our general cleaning and hygiene advice This can be found at www schuchmann de mediathek 5 1...

Page 24: ...rer s specifications Disinfect according to the manufacturer s specifications as required Damages to the frame mounting parts and accessories cracks breaks corrosion bent or missing parts Strength of...

Page 25: ...5 stating the serial number of the product Necessary spare parts and accessories must only be installed by trained personnel 5 5 Duration of use and re use The expected duration of use of our product...

Page 26: ...art of the product and must be passed on to the new user No disassembly is required prior to re use In the case of storage it is recommended to fold the product to the smallest dimension to save space...

Page 27: ...4cm E Armrest height 13 5cm 17cm 20cm F Back width 29cm 34cm 41cm G Lower leg length toilet seat 22 34cm 27 39cm 34 44cm H Back height 42cm 50cm 62cm I Max toilet height which the product can be posit...

Page 28: ...s This begins with the delivery or handover of the goods Should a verifiable ma terial or manufacturing fault occur within this time period we shall after carriage paid return to us view the indicated...

Page 29: ...d directives and standards Verordnung EU 2017 745 ber Medizinprodukte vom 05 April 2017 Regulation EU 2017 745 on medical devices of 5 April 2017 DIN EN 12182 2012 Technische Hilfen f r behinderte Men...

Page 30: ...ame and address of the manufacturer specialist dealer supplying the product This product was manufactured by This product has been delivered by the following specialist dealer Schuchmann GmbH Co KG Ru...

Page 31: ...31 Notes...

Page 32: ...schuchmann de GA 57 EN_1 0...

Reviews: