![SCHNIER 810353 Operating Manual Download Page 6](http://html1.mh-extra.com/html/schnier/810353/810353_operating-manual_1213810006.webp)
Operating manual 810353-BALDE-150220
Version 20.02.2015
Page 6 of 36
3.2.
Further requirements for the surrounding system
The HV generator must only be used in electrostatic systems within a
temperature range
of 15°C to 50°C
and with a relative humidity between
10% and 70%
(not condensing).
The HV generator is intended for
operation in a specific stationary
system in an industrial
environment
. Due to the occurrence of conduc-
tive or radiated interference, there may be difficulties in ensuring electro-
magnetic compatibility in other environments.
To prevent hazards the entire system must undergo a risk analysis. Es-
pecially the Performance Level required in the above mentioned
EN50348 standard for safety functions can only be met via a safety con-
cept of the entire system.
All poles of the energy supply of the high-voltage generator must be able
to be disconnected from power with a circuit breaker, since the generator
itself has no circuit breaker.
The system must have an emergency stop switch, which also discon-
nects all poles of the power supply of the generator.
The power supply must comply with the Overvoltage category III or bet-
ter. The supply wire of the power supply must be fused with maximum 16
A.