Operating instructions
Pull-wire emergency-stop switches

ZQ 700 AS

EN

1.6  Warning about misuse

In case of improper use or manipulation of the safety switch-
gear, personal hazards or damages to machinery or plant 
components cannot be excluded The relevant requirements 
of the standard EN ISO 13850 must be observed

1.7  Exclusion of liability

We shall accept no liability for damages and malfunctions resulting from 
defective mounting or failure to comply with this operating instructions 
manual The manufacturer shall accept no liability for damages result-
ing from the use of unauthorised spare parts or accessories

For safety reasons, invasive work on the device as well as arbitrary re-
pairs, conversions and modifications to the device are strictly forbidden; 
the manufacturer shall accept no liability for damages resulting from 
such invasive work, arbitrary repairs, conversions and/or modifications 
to the device

2.  Product description

2.1  Ordering code

This operating instructions manual applies to the following types:

ZQ 700 

-AS

No.

Option

Description

ST

Connector plug M 12

FK

Flat cable connection

Only if the information described in this operating instructions 
manual are realised correctly, the safety function and there-
fore the compliance with the Machinery Directive is maintained

2.2  Special versions

For special versions, which are not listed in the order code below 21, 
these specifications apply accordingly, provided that they correspond to 
the standard version

2.3  Destination and use

The emergency stop switch meets the requirements of EN ISO 13850, 
IEC/EN 60947-5-1 and IEC/EN 60947-5-5 Pull-wire emergency stop 
switches are used on machinery and plants, where triggering the emer-
gency stop command must be enabled at arbitrary points on the wire run

If the tensioned pull-wire is pulled or in case of wire breakage, the 
switching function of the pull-wire emergency stop switch is activated 
(refer to image 1)

F

1

0

0

Image 1: position indication and actuation

Design/operating principle

The pull-wire emergency stop switches are brought into the operational 
condition by the proper pre-tensioning of a maximum 10 m long wire 
The inner switching elements have 2 contacts; in tensioned condition, 
the NC contacts are closed

After actuation of the switching function, a latching mechanism main-
tains the stop command until the switch is released by pushing the blue 
reset button Prior to the reset of the stop signal, the reason why the 
switch has been actuated must be determined The switch can only 
be reset if the switch is correctly pre-tensioned (position indication in 
central position, refer to image 1)

An AS-Interface Safety at Work component functions on the basis of an 
individual code generator (8 × 4 bit) This safety code is cyclically trans-
mitted over the AS-i network and monitored by the ASM safety monitor 
The component status can be evaluated through a PLC with AS-Inter-
face master The safety-related functions are enabled by means of the 
AS-i safety monitor

The user must evaluate and design the safety chain in  
accordance with the relevant standards and the required 
safety level

2.4  Technical data

Standards:

 

EN 60947-5-1, EN 60947-5-5, EN ISO 13850, 

 

EN 50295, EN ISO 13849-1, IEC 61508

Enclosure:

 

glass-fibre reinforced thermoplastic, 

 self-extinguishing

Cover:

 

glass-fibre reinforced thermoplastic,  

 self-extinguishing

Wire length:

 

max 10 m depending in relation to the  

range of ambient temperature (see image 3)

Switching system:

 

Snap action, positive break NC

Mechanical life:

 

≥ 100.000 operations

Switching frequency: 

max 1/s

Response time:

 

< 100 ms

Connection:

 

Connector plug M12, 4-pole or FK

Electrical data - AS-Interface:

AS-i supply voltage:

 

180  316 VDC, through AS-Interface,  

reverse polarity-proof (stabilised PELV unit)

AS-I power consumption:

 

≤ 0,05 A

AS-i Device insulation:

 

internal short-circuit proof

AS-I specification:

Version:

 

V 30

Profile:

 S-0BFF

IO-Code: 

0×0

ID-Code: 

0×B

ID-Code 1: 

0×F

ID-Code 2: 

0×F

AS-interface inputs:

Channel 1:

 

DI 0 / DI 1 = dynamic code transmission

Channel 2:

 

DI 2 / DI 3 = dynamic code transmission

AS-interface outputs:

DO 0  DO 3:

 

no function

AS-Interface parameter port:

P0:

 

Channel 2 switched

P1 … P3: 

no function

Input module address:

 

0, preset to address 0,  

can be changed through AS-interface bus master  

or hand-held programming device

LED switching conditions display (internal)

LED yellow: 

Channel 1, SaW-Bit 01

LED green-red (AS-i Duo LED):

 

AS-Interface supply voltage /  

AS-Interface communication  

error / slave address = 0  

or periphery error detected

LED yellow:

 

Channel 2, SaW-Bit 23

Summary of Contents for ZQ 700 AS

Page 1: ...he entire machinery or plant The safety switchgear must be exclusively used in accordance with the versions listed below or for the applications authorised by the manufac turer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this operating instruc tions manual t...

Page 2: ... switching elements have 2 contacts in tensioned condition the NC contacts are closed After actuation of the switching function a latching mechanism main tains the stop command until the switch is released by pushing the blue reset button Prior to the reset of the stop signal the reason why the switch has been actuated must be determined The switch can only be reset if the switch is correctly pre ...

Page 3: ...ibrations in the wire on machines with high vibrations it is recommended to realise the individu al support length differently Assembly refer to image 2 6 4 2 3 6 5 6 1 0 1m 2 5m max 10m 4 6 3 2 A B 9 8 2 3 0 1m 2 5m max 10m 1 8 2 7 A B 3 9 Image 2 mounting of the components Key 1 Pull wire with red PVC sheath Ø 5 mm steel core Ø 3 mm 2 Eyebolt 3 Nut 4 Wire clamp 5 Tensioner 6 Wire thimble 7 Shack...

Page 4: ...ion time typically 0 1 0 5 s The configuration of the safety monitor must be tested and confirmed by a qualified and authorised safety expert safety engineer 5 3 Status signal safety release The safety release status signal from a Safety at Work slave can be cyclically queried by the control system through the AS i master To thiseffect the 4 input bits with the varying SaW code of a Safety at Work...

Page 5: ...ion indicator 7 2 Maintenance A regular visual inspection and functional test including the following steps is recommended 1 Check the functionality of the switch by actuating the wire 2 Check the cable entries and the wire connections 3 Remove particles of dust and soiling 4 Check the wire tension through the wire position indication and check the wire and the wire guides for damages and proper f...

Page 6: ...iver Wacker Möddinghofe 30 42279 Wuppertal 9 Appendix 9 1 EC Declaration of conformity K A Schmersal GmbH Co KG Möddinghofe 30 D 42279 Wuppertal Postfach 24 02 63 D 42232 Wuppertal Phone 49 0 2 02 64 74 0 Telefax 49 0 2 02 64 74 1 00 E Mail info schmersal com Internet http www schmersal com Place and date of issue Wuppertal September 9 2014 Authorised signature Philip Schmersal Managing Director E...