schmersal TQ 900 Operating Instructions Download Page 1

1

TQ 900

Operating instructions
Pull-wire switches

EN

1.  About this document

1.1  Function

This operating instructions manual provides all the information required 
for the mounting, set-up and commissioning to ensure the safe opera-
tion and disassembly of the safety switchgear. he operating instructions 
must be available in a legible condition and a complete version in the 
vicinity of the device.

1.2  Target group: authorised qualified personnel

All operations described in this operating instructions manual must 
be carried out by trained specialist personnel, authorised by the plant 
operator only.

Please make sure that you have read and understood these operating 
instructions and that you know all applicable legislations regarding 
occupational safety and accident prevention prior to installation and 
putting the component into operation.

The machine builder must carefully select the harmonised standards to 
be complied with as well as other technical specifications for the selec-
tion, mounting and integration of the components.
 

1.3  Explanation of the symbols used

Information, hint, note:

This symbol is used for identifying useful additional information.

Caution:

 Failure to comply with this warning notice could 

lead to failures or malfunctions.

Warning:

 Failure to comply with this warning notice could 

lead to physical injury and/or damage to the machine.

1.4  Appropriate use

The product must be exclusively used in accordance with the versions 
listed below or for the applications authorised by the manufacturer. 
Detailed information regarding the range of applications can be found in 
the chapter "Product description".

1.5  General safety instructions

The user must observe the safety instructions in this operating instruc-
tions manual, the country-specific installation standards as well as all 
prevailing safety regulations and accident prevention rules.

Further technical information can be found in the Schmersal 
catalogues or in the online catalogue on the Internet:  
www.schmersal.net.

The information contained in this operating instructions manual is pro-
vided without liability and is subject to technical modifications.

There are no residual risks, provided that the safety instructions as well 
as the instructions regarding mounting, commissioning, operation and 
maintenance are observed.

1.6  Warning about misuse

In case of inadequate or improper use or manipulations of  
the component, personal hazards or damage to machinery  
or plant components cannot be excluded.

1.7  Exclusion of liability

We shall accept no liability for damages and malfunctions resulting from 
defective mounting or failure to comply with this operating instructions 
manual. The manufacturer shall accept no liability for damages result-
ing from the use of unauthorised spare parts or accessories.

For safety reasons, invasive work on the device as well as arbitrary re-
pairs, conversions and modifications to the device are strictly forbidden; 
the manufacturer shall accept no liability for damages resulting from 
such invasive work, arbitrary repairs, conversions and/or modifications 
to the device.

Content

About this document

1.1  Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.2 

Target group: authorised qualiied personnel

. . . . . . . . . . . . . . . . . . 1

1.3  Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.4  Appropriate use  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.5  General safety instructions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.6  Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.7  Exclusion of liability  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

Product description

2.1  Ordering code  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.2  Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.3  Destination and use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.4  Technical data  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

Mounting

3.1  General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
3.2  Dimensions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

Electrical connection

4.1  General information for electrical connection. . . . . . . . . . . . . . . . . . 3
4.2  Contact variants . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

Set-up and maintenance

5.1  Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
5.2  Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

Disassembly and disposal

6.1  Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
6.2  Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

Appendix

7.1  EC Declaration of conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

12.2015 / 101

186350-EN / 

ACE-573767 / F

EN

Operating instructions. . . . . . . . . . . . .pages 1 to 6

Translation of the original operating instructions

Summary of Contents for TQ 900

Page 1: ...ention rules Further technical information can be found in the Schmersal catalogues or in the online catalogue on the Internet www schmersal net The information contained in this operating instructions manual is pro vided without liability and is subject to technical modifications There are no residual risks provided that the safety instructions as well as the instructions regarding mounting commi...

Page 2: ...ted insulation voltage Ui 500 V Thermal test current Ithe 6 A Rated operating current voltage Ie Ue 4 A 230 VAC 1 A 24 VDC Utilisation category AC 15 DC 13 Required short circuit current 1000 A Max fuse rating 6 A gG D fuse EN 60269 1 Ambient temperature 25 C 70 C Wire length max 75 m depending in relation to the range of ambient temperature see image 3 Mechanical life 1 million operations AWG 14 ...

Page 3: ...es must be sealed by means of locking screws included in delivery tightening torque 4 Nm 7 The cover screws must be tightened uniformly tightening torque 1 Nm Accessories cable gland Ordering code 103006013 Authorised cable diameter 6 12 mm Tightening torque 4 5 Nm 4 2 Contact variants The symbols are shown for the switch in non actuated condition TQ 900 11 TQ 900 02 14 13 22 21 12 11 22 21 TQ 900...

Page 4: ...trônica Industrial Ltda Av Brasil nº 815 Jardim Esplanada CEP 18550 000 Boituva SP Brazil Phone 55 0 15 32 63 9866 Fax 55 0 15 32 63 9890 E Mail vendas schmersal com br Internet http www schmersal com br Place and date of issue Boituva 28 May 2015 Authorised signature Marco Antonio De Dato Head of Engineering and Design EC Declaration of conformity Translation of the original Declaration of Confor...

Reviews: