background image

1

TQ 700 S

Operating instructions
Pull-wire switches

EN

1.  About this document

1.1  Function

This operating instructions manual provides all the information required 
for the mounting, set-up and commissioning to ensure the safe opera-
tion and disassembly of the safety switchgear. The operating instruc-
tions must be available in a legible condition and a complete version in 
the vicinity of the device.

1.2  Target group: authorised qualified personnel

All operations described in this operating instructions manual must 
be carried out by trained specialist personnel, authorised by the plant 
operator only.

Please make sure that you have read and understood these operating 
instructions and that you know all applicable legislations regarding 
occupational safety and accident prevention prior to installation and 
putting the component into operation.

The machine builder must carefully select the harmonised standards 
to be complied with as well as other technical specifications for the 
 selection, mounting and integration of the components.
 

1.3  Explanation of the symbols used

Information, hint, note:

This symbol is used for identifying useful additional information.

Caution:

 Failure to comply with this warning notice could 

lead to failures or malfunctions.

Warning:

 Failure to comply with this warning notice could 

lead to physical injury and/or damage to the machine.

1.4  Appropriate use

The product must be exclusively used in accordance with the versions 
listed below or for the applications authorised by the manufacturer. 
Detailed information regarding the range of applications can be found in 
the chapter "Product description".

1.5  General safety instructions

The user must observe the safety instructions in this operating instruc-
tions manual, the country-specific installation standards as well as all 
prevailing safety regulations and accident prevention rules.

Further technical information can be found in the Schmersal 
catalogues or in the online catalogue on the Internet:  
www.schmersal.net.

The information contained in this operating instructions manual is  
provided without liability and is subject to technical modifications.

There are no residual risks, provided that the safety instructions as well 
as the instructions regarding mounting, commissioning, operation and 
maintenance are observed.

1.6  Warning about misuse

In case of inadequate or improper use or manipulations of  
the component, personal hazards or damage to machinery  
or plant components cannot be excluded.

Content

About this document

1.1  Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.2 

Target group: authorised qualiied personnel

. . . . . . . . . . . . . . . . . . 1

1.3  Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
1.4  Appropriate use  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.5  General safety instructions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.6  Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.7  Exclusion of liability  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

Product description

2.1  Ordering code  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.2  Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.3  Destination and use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.4  Technical data  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

Mounting

3.1  General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
3.2  Dimensions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

Electrical connection

4.1  General information for electrical connection. . . . . . . . . . . . . . . . . . 3
4.2  Contact variants . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
4.3  Switch travel diagrams. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

Set-up and maintenance

5.1  Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
5.2  Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

Disassembly and disposal

6.1  Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
6.2  Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

Appendix

7.1  EC Declaration of conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

04.2015 / 

ACE-574454-EN / E

EN

Operating instructions. . . . . . . . . . . . .pages 1 to 4

Translation of the original operating instructions

Summary of Contents for TQ 700 S

Page 1: ...range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this operating instruc tions manual the country specific installation standards as well as all prevailing safety regulations and accident prevention rules Further technical information can be found in the Schmersal catalogues or in the online catalo...

Page 2: ... the standard version 2 3 Destination and use Pull wire switches are used to give signals to start machines and to open or close electrically driven doors and gates If the pull wire is pulled the switching function of the pull wire switch is activated 2 4 Technical data Standards IEC EN 60947 5 1 Enclosure thermoplastic Cover thermoplastic Protection class IP67 to IEC EN 60529 Protection class II ...

Page 3: ...700 20S ST 1 2 3 4 21 13 22 14 1 2 3 4 21 11 22 12 1 2 3 4 23 13 24 14 Key A Positive break NC contact 4 3 Switch travel diagrams TQ 700 11S TQ 700 02S 0 4 3 3 7 5 13 14 21 22 0 3 3 7 5 11 12 21 22 TQ 700 20S 0 4 5 13 14 23 24 TQ 700 11S 40N TQ 700 02S 40N 0 3 2 5 13 14 21 22 0 2 5 11 12 21 22 TQ 700 20S 40N 0 3 5 13 14 23 24 5 Set up and maintenance 5 1 Functional testing The function of the comp...

Page 4: ...planada CEP 18550 000 Boituva SP Brasil Phone 55 0 15 32 63 9866 Fax 55 0 15 32 63 9890 E Mail vendas schmersal com br Internet http www schmersal com br Place and date of issue Boituva 8 July 2014 Authorised signature Marco Antonio De Dato Head of Engineering and Design EC Declaration of conformity Translation of the original Declaration of Conformity ACE Schmersal Eletroeletrônica Industrial Ltd...

Reviews: