2

Operating instructions

Safety foot switches

TFH 232 AS

EN

1.7  Exclusion of liability

We shall accept no liability for damages and malfunctions resulting from 

defective mounting or failure to comply with this operating instructions 

manual The manufacturer shall accept no liability for damages result-

ing from the use of unauthorised spare parts or accessories

For safety reasons, invasive work on the device as well as arbitrary re-

pairs, conversions and modifications to the device are strictly forbidden; 

the manufacturer shall accept no liability for damages resulting from 

such invasive work, arbitrary repairs, conversions and/or modifications 

to the device

2.  Product description

2.1  Ordering code

This operating instructions manual applies to the following types:

TFH 232 

-AS 

➁➂➃

No. Option

Description

ST

Connector plug M 12

UE

Overlapping contacts

D

with pressure point

R

with latching

Only if the information described in this operating instruc-

tions manual are realised correctly, the safety function and 

therefore the compliance with the Machinery Directive is 

maintained

2.2  Special versions

For special versions, which are not listed in the order code below 21, 

these specifications apply accordingly, provided that they correspond to 

the standard version

2.3  Destination and use

These robust safety foot switches are particularly suitable for indus-

trial applications All safety foot switches are mounted with a shield to 

protect against unintentional operation When the foot pedal is actuated 

to as far as the pressure point, the NO contact is closed If, in case of 

danger, the pedal is actuated beyond the pressure point, then the posi-

tive break NC contact is opened and mechanically latched

All safety foot switches are mounted with a shield to protect against un-

intentional operation When the foot pedal is actuated to as far as pres-

sure point, the NO contact is closed If, in case of danger, the pedal is 

actuated beyond the pressure point, then the positive break NC contact 

is opened and mechanically latched by means of a locking device and 

a spring in the housing Reset operation is carried out by means of the 

blue push button located on the topside of the enclosure This button 

pushes the locking device back to its original position The unlocking 

button is equipped with a rubber cap, protecting the inner compartment 

of the foot switch enclosure against moisture and dirt

Design/operating principle

The following functionality is not set in the TFH 232 AS safety foot switch:

Representation:

Condition:

Function

0

0

1

0

0

0

21

13

22

14

21

13

22

14

21

13

22

14

21

13

22

14

A

A

A

A

not actuated

 No authorised 
operation

actuated up to pressure 
point

Safety release

pushed-through

No authorised 
operation

Unlock

No authorised 
operation

An AS-Interface Safety at Work component functions on the basis of an 

individual code generator (8 x 4 bit) This safety code is cyclically trans-

mitted over the AS-i network and monitored by the ASM safety monitor 

The component status can be evaluated through a PLC with AS-Inter-

face master The safety-related functions are enabled by means of the 

AS-i safety monitor 

The user must evaluate and design the safety chain in  

accordance with the relevant standards and the required 

safety level

2.4  Technical data

General data 

Standards:

 

EN 50295, EN 60947-5-1, EN 60947-5-5, 

IEC 61508, EN ISO 13849-1

Operating principle:

 

electromechanical

Material Enclosure/cap/cover:

 

Aluminium die-cast

Enclosure coating:

 

powder-coated thermoplastic

Material of the pedal:

 

Plastic, glass-fibre reinforced 

thermoplastic, self-extinguishing

Response time:

 

< 100 ms

Mechanical data 

Switching principle:

 

slow action, 1 NO and 1 NC, positive break 

A

Execution of the electrical connection:

 

M12 connector plug, 5 poles

Mechanical life:

 

 > 200,000 operations

Switching frequency:

 

max 1/s

Resistance to shock:

 

30 g / 11 ms

Resistance to vibration:

 

10 … 150 Hz (035 mm / 5 g)

Ambient conditions 

Ambient temperature:

 

-25° C  +60° C

Storage and transport temperature:

 

 -25 °C … +85 °C

Relative humidity:

 

30 % … 95%, no condensation, no icing

Protection class:

 

IP65

Insulation values to IEC/EN 60664-1: 

Rated impulse withstand voltage Uimp: 

08 kV

Rated insulation voltage U

i

:

 

32 VDC

Overvoltage category:

 

III

Degree of pollution:

 

3

Electrical data - AS-Interface 

AS-i supply voltage:

 

18,0  31,6 VDC, protection against 

polarity reversal (stabilised PELV units)

AS-I power consumption:

 

≤ 0,05 A

AS-i Device insulation:

 

internal short-circuit proof

AS-i specification:

 

Safety-Slave

Version:

 

V 30

Profile:

 

S-0BFF

AS-i inputs: 

 

- Channel 1:

 

Data bits DI 0/DI 1 = dynamic code transmission

- Channel 2:

 

Data bits DI 2/DI 3 = dynamic code transmission

Summary of Contents for TFH 232 AS

Page 1: ...r for the applications authorised by the manufac turer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this operating instruc tions manual the country specific installation standards as well as all prevailing safety regulations and accident prevention rules Furt...

Page 2: ... pushes the locking device back to its original position The unlocking button is equipped with a rubber cap protecting the inner compartment of the foot switch enclosure against moisture and dirt Design operating principle The following functionality is not set in the TFH 232 AS safety foot switch Representation Condition Function 0 0 1 0 0 0 21 13 22 14 21 13 22 14 21 13 22 14 21 13 22 14 A A A A...

Page 3: ...nection 4 1 General information for electrical connection The electrical connection may only be carried out by authorised personnel in a de energised condition The connection to the AS Interface system is realised through an M12 connector The connector is A coded the wiring configuration is deter mined as follows to EN 50295 Pin assignment M12 connector 5 pole 3 2 5 1 4 PIN 1 AS i PIN 2 spare PIN ...

Page 4: ...hannel 2 activated Channel 2 disabled 1 2 3 7 Set up and maintenance 7 1 Functional testing The safety function of the safety components must be tested The following conditions must be previously checked and met 1 Check the integrity of the cables and connections 2 Check the switch enclosure for damage 3 Check the functionality of the switch by actuating the safety foot switch 7 2 Maintenance The ...

Page 5: ...cumentation Ulrich Loss Möddinghofe 30 42279 Wuppertal 5 TFH 232 AS Operating instructions Safety foot switches EN 9 Appendix 9 1 EC Declaration of conformity Place and date of issue Wuppertal January 10 2011 Authorised signature Heinz Schmersal Managing Director EC Declaration of conformity Translation of the original declaration of conformity K A Schmersal GmbH Industrielle Sicherheitsschaltsyst...

Page 6: ...H Industrielle Sicherheitsschaltsysteme Möddinghofe 30 D 42279 Wuppertal Postfach 24 02 63 D 42232 Wuppertal Phone 49 0 2 02 64 74 0 Telefax 49 0 2 02 64 74 1 00 E Mail info schmersal com Internet http www schmersal com ...

Reviews: