schmersal T 335 AS Operating Instructions Manual Download Page 4

4

Operating instructions

Position switch with safety function

T 335 AS

T 336 AS

EN

Positioning the lever (.H)

10° 10°

10°

10°

The roller lever can be repositioned over 360° on the toothed shaft in 

10° steps. Unscrew the hexagonal screw approx. 4 mm, reposition the 

lever in the desired position and retighten the screw

Length-adjustable lever (7H-2138)

To adjust the length of the lever, unscrew the fixing screw of the lever 

Firmly retighten the screw after the length adjustment

3.5  Actuation of the position switches

Top plunger

A

Key

A End stop

Roller plunger

max. 30°

Cam disc

front side

Trailing edge

4.  Rear side Electrical connection

4.1  General information for electrical connection

The electrical connection may only be carried out by  

authorised personnel in a de-energised condition

The connection to the AS-Interface system is realised through an M12 

connector or an AS-i flat cable clamp The wiring configuration of the 

M12 connector is defined as follows (to EN 50295):

Pin assignment

M12 connector

5-pole

3

2

5

1

4

PIN 1: AS-i +

PIN 2: spare

PIN 3: AS-i −

PIN 4: spare

PIN 5: FE (functional earth connection)

Connection Functional earth connection only available with metal 

enclosure

5.  Functions and configuration

5.1  Programming the slave address

The slave address is programmed through the M12 connector Any 

address from 1 to 31 can be set by means of the AS-i bus master or a 

hand-held programming device

5.2  Configuration of the safety monitor

The safety switch can be configured in the ASIMON configuration 

software with the following monitoring devices (refer to ASIMON 

manual):

Double channel dependent

• Optionally with startup test

• Synchronisation time typically 05 - 20 s

Double channel dependent with filtering

The use of this monitoring device is especially advantageous on safety 

guards where bounce or vibration against the mechanical stop upon 

closing is a problem

• Optionally with startup test

• Stabilising time typically: 05 10 s

• Synchronisation time typically 50 - 100 s

The safety-monitoring module is only released after expiration of the 

stabilising time; the synchronization time always must exceed the 

stabilising time

The configuration of the safety monitor must be tested and 

confirmed by a qualified and authorised safety expert/safety 

engineer

5.3  Status signal "safety release"

The "safety release" status signal from a Safety at Work slave can be 

cyclically queried by the control system through the AS-i master  To 

that effect, the 4 input bits with the varying SaW code of a Safety at 

Work slave are evaluated through an OR operation with 4 inputs in the 

control system

Summary of Contents for T 335 AS

Page 1: ...functionality of the entire machine or plant The safety switchgear must be exclusively used in accordance with the versions listed below or for the applications authorised by the manufacturer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this operating instruc...

Page 2: ...yclically transmitted over the AS i network and monitored by the ASM safety monitor The component status can be evaluated through a PLC with AS Interface master The safety related functions are enabled by means of the AS i safety monitor The user must evaluate and design the safety chain in accordance with the relevant standards and the required safety level 2 4 Technical data Standards EN 60947 5...

Page 3: ...60 66 5 7 3 30 16 5 76 M12x1 20 30 30 5 17 38 23 24 22 24 FK T 336 AS 9 5 Ø 5 3 60 66 5 30 7 3 M12x1 40 5 16 5 76 30 5 15 5 17 38 24 23 FK 24 Actuator heads T 335 336 AS Selection and dimensions refer to SCHMERSAL Main catalogue Safety Technology 3 3 Changing the switching function 4VH 4V7H 4V10H Position switches with 4V actuating head can be set so that they are switched either only clockwise on...

Page 4: ...onfiguration 5 1 Programming the slave address The slave address is programmed through the M12 connector Any address from 1 to 31 can be set by means of the AS i bus master or a hand held programming device 5 2 Configuration of the safety monitor The safety switch can be configured in the ASIMON configuration software with the following monitoring devices refer to ASIMON manual Double channel depe...

Page 5: ...purposes or for the control programme Table 3 diagnostic information P0 P3 Parameter bit Condition 1 Condition 0 0 Channel 2 activated Channel 2 disabled 1 2 3 7 Set up and maintenance 7 1 Functional testing The safety function of the safety components must be tested The following conditions must be previously checked and met 1 Check the switch enclosure for damage 2 Check the free movement of the...

Page 6: ... Type See ordering code Description of the component Positive break position switch for safety functions with integrated AS i Safety at Work Relevant Directives Machinery Directive EMC Directive RoHS Directive 2006 42 EC 2014 30 EU 2011 65 EU Applied standards DIN EN 60947 5 1 2010 DIN EN ISO 13849 1 2016 IEC 61508 parts 1 7 2010 Person authorised for the compilation of the technical documentation...