16
EN
SLG 425I
Operating instructions
Safety light grid
5.5 Cleaning
If the optics cover of the sensors is extremely soiled, the OSSD outputs
can be disabled. Clean with a soft cloth without exercising pressure.
The use of agressive, abrasive or scratching cleaning agents, which
could attack the surface, is prohibited.
6. Diagnostic
6.1 LED status information
Receiver
Function
LED colour
Description
Multifunction
Blanking
Signal reception
Restart
OSSD OFF
OSSD ON
Protection field
Multifunction
green
Function display, beam coding
Blanking
blue
Protection field(s) inactive (blanking)
Signal reception
orange
Evaluation of the signal reception
Restart
yellow
Input for command device
OSSD OFF
red
Safety outputs signal condition OFF
OSSD ON
green
Safety outputs signal condition ON
Transmitter
Function
LED colour
Description
Transmitting
Status
Protection field
Transmitting
orange
Transmitter active
Status
green
Function display, beam coding
Receiver
LED
Status LED
Description
OSSD ON
ON
Protection field clear
Flashing
Diagnostic mode active
OSSD OFF
ON
Protection field interrupted, system or configuration error
Flashing
Diagnostic mode active, error output refer to Fault diagnostic table
Restart
ON
Start or restart interlock (manual reset) active, signal expected at output WA
Signal reception
ON/flashing
Signal reception too low, check alignment and installation height between
transmitter and receiver
Cleaning the black profile cover
OFF
Alignment between transmitter and receiver OK
Blanking
1 flashes
Fixed blanking of the protection field(s)
Multifunction
1 flashes
Muting (complete protection field)
2 flashes
Muting (only teached protection field)
3 flashes
Muting through BUS control
4 flashes
reserved
5 flashes
Beam coding A is active
Transmitter
LED
Status LED
Description
Transmitting
ON
Standard operation, transmitter active
Flashing
Configuration error
Status
Flashing
Beam coding A is active