4.9  Accessories, included in delivery

Mounting kit MS-1100

The mounting kit consists of 4 pcs steel angles and 8 pcs fixing 

screws (Type Torx plus 10IP)

5,5

17

28

24

7

11

24

38

MSD5 spacer

The kit consists of 2 pcs spacers Available as of a protection zone 

height of 1050 mm Mounting must be used in case of vibrations 

M4

10

8

33

7,7

4.10 Optional accessory

Centre support MS-1110

Mounting kit consists of 2 pcs steel angles and 4 pcs spacers for 

central fixing

4

27,8

11,5

19,5

11,5

54,3

69

38

5,5

3

27

3

7

 

 

Connecting cable for emitter / receiver (4-pole)

Article No. Designation (description)

Length

101207741 KA-0804 (female connector M12, 4-pole)

5 m

101207742 KA-0805 (female connector M12, 4-pole)

10 m

101207743 KA-0808 (female connector M12, 4-pole)

20 m

Connecting cable for receiver (5-pole)*

Article No. Designation (description)

Length

103010816 A-K5P-M12-S-G-5M-BK-2-X-A-4-69 

(Female connector M12, 5-pole)

5 m

103010818 A-K5P-M12-S-G-10M-BK-2-X-A-4-69 

(Female connector M12, 5-pole)

10 m

103010820 A-K5P-M12-S-G-15M-BK-2-X-A-4-69 

(Female connector M12, 5-pole)

15 m

* For use in the operating mode Restart Interlock (manual reset)

Adapter cable for alignment kit:

Article No. Designation (description)

Length

103034548 KA-0827 (cable for alignment mode 

M12 coupling (female/male connector), 4-pole)

03 m

Adapter cable for parameter setting

Article No. Designation (description)

Length

103016100 KA-0896 (pushbutton with command device)

25 m

Test rod PLS

The test rod is used for testing the protection field

MSD4 Vibration damper

Kit consists of: 8 pcs vibration dampers 15 x 20 mm, 8 pcs M5 cylinder 

head screws with hexagon socket, 8 pcs spring washers Mounting 

using MS-1100

The MSD4 vibration damper kit is recommend to be used for damping 

vibrations and oscillations on the AOPD For applications with higher 

mechanical stresses, eg presses, punching machines, we recommend 

the MSD4 kit In this way, the availability of the AOPD is increased

Summary of Contents for SLC440COM Series

Page 1: ...ion 1 1 2 Target group authorised qualified personnel 1 1 3 Explanation of the symbols used 1 1 4 Appropriate use 2 1 5 General safety instructions 2 1 6 Warning about misuse 2 1 7 Exclusion of liabil...

Page 2: ...ccept no liability for damages and malfunctions resulting from defective mounting or failure to comply with this operating instructions manual The manufacturer shall accept no liability for damages re...

Page 3: ...oad inductance 4 0 2H Function protective mode automatic restart interlock setting mode Connection Emitter connector M12 4 pole Receiver connector M12 5 pole Ambient temperature 10 C 50 C Storage temp...

Page 4: ...ction zone interrupted OSSD signal low Green ON state protection zone uninterrupted OSSD signal high 2 9 2 Restart Interlock operation In the operating mode restart interlock the safety switching outp...

Page 5: ...ta or cyan For the parameter setting follow the instructions as described in the section Parameter setting with adapter cable KA 0896 4 Mounting 4 1 General conditions The following guidelines are pro...

Page 6: ...llow operating mode restart interlock 3 Adjust the emitter and receiver so that they are in the middle of the angular range for a green or yellow indication Fix the position with the two screws for ea...

Page 7: ...is exposed to serious injuries To calculate the minimum distances of the safety guards with regards to the hazardous point the EN ISO 13855 and EN ISO 13857 must be observed If an overlap of the prote...

Page 8: ...e 1 Locate the height of the upper edge of the hazardous area a left table column 2 Locate the height of the protection area b upper table row 3 CRO is to be taken from the crossing point of both axes...

Page 9: ...h neighbouring safety light barriers grids of the same type AOPD is excluded If two or more applications are arranged so that mutual interference is possible this should be eliminated with a partition...

Page 10: ...C440COM ER 0970 xx Ls 1024 13 1011 mm 4 8 Dimensions 4 8 1 Dimensions emitter and receiver SLC440COM All measurements in mm 75 A B C 22 2 24 7 7 33 27 8 Type A Protected height 1 B Mounting dimension...

Page 11: ...on description Length 103010816 A K5P M12 S G 5M BK 2 X A 4 69 Female connector M12 5 pole 5 m 103010818 A K5P M12 S G 10M BK 2 X A 4 69 Female connector M12 5 pole 10 m 103010820 A K5P M12 S G 15M BK...

Page 12: ...ed BK 24 VDC BN 0 VDC BU Release restart GY 24 VDC BN OSSD 2 BK OSSD 1 WH 0 VDC BU Not connected WH Protective mode Automatic active Delivery state Pushbutton S1 not connected Restart Interlock manual...

Page 13: ...of the emitter is correctly connected to the emitter and the connecting cable of the receiver is correctly connected to the receiver 4 The double insulation between the light curtain output and an ex...

Page 14: ...Green static Status of OSSD safety switch outputs is ON protection field is clear OSSD OFF Red static Status of OSSD safety switch outputs is OFF the protection field is interrupted Restart interlock...

Page 15: ...003 This device complies with Industry Canada s license exempt RSS standard s Operation is subject to the following two conditions 1 This device may not cause interference and 2 This device must accep...

Page 16: ...205 13144609 Person authorised for the compilation of the technical documentation Oliver Wacker M ddinghofe 30 42279 Wuppertal Place and date of issue M hldorf May 11 2020 Authorised signature Klaus S...

Reviews: