schmersal RSS36 AS Operating Instructions Manual Download Page 3

3

RSS36 AS

Operating instructions

Safety sensor

EN

AS-i parameter bits: 

 

- P0:

 

Actuator present 

- P1:

 

Hysteresis signal (FID)g 

- P2:

 

Tamper protection time active (FID) 

- P3:

 

Device error (FID)

Actuator detection (AD): 

 

- P0 … P3: 

Actuator number 0, 01 - 15

Parameter request:

 

 default value parameter request "1111" (0xF)

AS-i Input module address:

 0 

- preset to address 0, can be changed through  

AS-interface bus master or hand-held programming device

LED switching conditions display: 

green/red LED (AS-i Duo LED):

 

Supply voltage / 

communication error / 

slave address = 0 /  

periphery error detected /  

Tamper protection time active

red LED:

 

Internal device error

yellow LED:

 

Device condition (enabling status) /  

hysteresis signal 

For use in NFPA 79 Applications only. Only for use in 

Pollution Degree 2 Environment. Adapters providing field 

wiring means are available from the manufacturer.  

Refer to manufacturers information.

2.6  Safety classification

Standards:

 

ISO 13849-1, IEC 61508

PL:

 e

Control Category:

 4

PFH value:

 

≤ 5.13 x 10

-10

 / h

PFD:

 

≤ 3.24 x 10

-5

SIL:

 

suitable for SIL 3 applications

 

Service life: 

20 years

3.  Mounting

3.1  General mounting instructions

During fitting, the requirements of ISO 14119 must be 

observed.

The universal mounting holes provide for a variable mounting by means 

of M4 screws. The component can be mounted in any position. The 

labelled surfaces of the safety sensor and the actuator have to be oppo-

site. The safety sensor must only be used within the assured switching 

distances ≤ s

ao

 and ≥ s

ar

.

The safety component and the actuator must be permanently 

fitted to the safety guards and protected against displacement 

by suitable measures (tamperproof screws, gluing, drilling, 

pinning).

To avoid any interference inherent to this kind of system and any reduc-

tion of the switching distances, please observe the following guidelines:

•  The presence of metal chips in the vicinity of the sensor is liable to 

modify the switching distance.

• Keep away from metal chips.

• Minimum distance between two sensors: 100 mm

Accessories (to be ordered separately)

Sealing kit

• Ordering code 101215048

• 8 plugs and 4 washers

•  to seal the mounting holes and as spacer 

 

(approx. 3 mm) to facilitate the cleaning below the mounting surface

• also suitable as tampering protection for the screw fixings.

 

Kit tamper-proof screws

• 4 x M4x25 incl. washers, ordering code 101217746

• 4 x M4x30 incl. washers, ordering code 101217747

3.2  Dimensions

All measurements in mm.

Safety sensor RSS36-…-ST-AS

106

91

74
78

9

25

4,

5

18.5

6,

2

M1

2

2

22

High Level Code

Actuator RST36-1 / RST36-1-R

91

78

25

22

Alternative suitable actuators with different design: refer to 

www.schmersal.net.  

3.3  Switching distance

The side allows for a maximum height misalignment (X) of sensor and 

actuator of ± 8 mm (e.g. mounting tolerance or due to guard door sag-

ging). The axial misalignment (y) is max. ± 18 mm.

Y

X

Latching versions X ± 5 mm, Y ± 3 mm.  

The latching force will be reduced by misalignment.

Summary of Contents for RSS36 AS

Page 1: ...tions can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this operating instructions manual labelled with the caution or w...

Page 2: ...trans mission when the safety guard is opened and maintaining the safe switched off condition for as long as the safety guard is open The safety switchgears are classified according to ISO 14119 as ty...

Page 3: ...the actuator have to be oppo site The safety sensor must only be used within the assured switching distances sao and sar The safety component and the actuator must be permanently fitted to the safety...

Page 4: ...control system through the AS i master To thiseffect the 4 input bits with the varying SaW code of a Safety at Work slave are evaluated through an OR operation with 4 inputs in the control system 5 4...

Page 5: ...green flashing Off Off Set static 0 Internal device error periphery error red green flashing Flashes 1 Off Set static 0 AS i error slave address 0 or communication error red depending on the condition...