5.  Set-up and maintenance

5.1  Functional testing

A check must be carried out to ensure that the projected safety function 

is effective.

The security function, the configuration of the DP switch 

and the jumper, as well  as the proper installation, must be 

 checked by the responsible security expert / security officer.

5.2  Maintenance

The passive fieldbox operates error-free if installed and used properly.

6.  Disassembly and disposal

6.1  Disassembly

Only disassemble the passive fieldbox if it is in de-energized state.

6.2  Disposal

Dispose of the passive fieldbox properly in accordance with national 

regulations and laws.

7.  Configuration

7.1  Configuration examples

3 configurations are shown respectively for the different SCHMERSAL devices. One configuration with long cable lengths (maximum),  

one configuration with medium cable lengths (medium) and one configuration with shorter cable lengths (small).

The following assumptions are made for the configuration examples listed in the table:

•  The examples represent maximum configurations. If individual cable lengths are shortened, larger systems are possible

•  2 x 1.5 mm² power supply wiring and 10 A fuse protection

•  Use of SCHMERSAL cables

•  The cable lengths listed in the table between power supply and the 1st field box, and between fieldboxes are maximum lengths.  

Reducing the individual cable lengths is not critical.

Device / configuration  

version

Max. number  

of devices

Equals number 

of fieldboxes

Length of the cable (A)  

up to the 1st fieldbox

Length of the cables (B)  

between the fieldboxes

Length of stub cables (C)  

for device connection

AZM 200 / Maximum

16

4

10.0 m

10.0 m

7.5 m

AZM 200 / Medium

20

5

7.5 m

7.5 m

5.0 m

AZM 200 / Small

22

5.5

7.5 m

5 m

3.5 m

MZM 100 / Maximum

18

4.5

10.0 m

10.0 m

7.5 m

MZM 100 / Medium

22

5.5

7.5 m

7.5 m

5.0 m

MZM 100 / Small

26

6.5

7.5 m

5 m

3.5 m

AZM 300 / Maximum

24

6

10.0 m

10.0 m

7.5 m

AZM 300 / Medium

28

7

7.5 m

7.5 m

5.0 m

AZM 300 / Small

31

8

7.5 m

5 m

3.5 m

RSS & CSS / Maximum

31

8

10.0 m

10.0 m

7.5 m

RSS & CSS / Medium

31

8

7.5 m

7.5 m

5.0 m

RSS & CSS / Small

31

8

7.5 m

5 m

3.5 m

Mixed / Maximum

24

6

10.0 m

10.0 m

7.5 m

Mixed / Medium

28

7

7.5 m

7.5 m

5.0 m

Mixed / Small

31

8

7.5 m

5 m

3.5 m

Mixed fitting of fieldbox:

 2 x MZM 100, 1 x AZM 300 and 1 x RSS / CSS

(A)

(B)

(C)

(B)

(C)

(C)

24 VDC

Power

Fieldbox

Fieldbox

Fieldbox

Devices

Devices

Devices

K. A. Schmersal GmbH & Co. KG

Möddinghofe 30, D - 42279 Wuppertal

Postfach 24 02 63, D - 42232 Wuppertal 

Phone:  +49 - (0)2 02 - 64 74 - 0 

Telefax:  +49 - (0)2 02 - 64 74 - 1 00

E-Mail: [email protected]

Internet: http://www.schmersal.com

Summary of Contents for PFB-SD-4M12-SD

Page 1: ...e passive fieldbox must only be used according to the following versions or for applications that are approved by the manufacturer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this operating instructions manual the country specific installation standards as w...

Page 2: ...ith the relevant standards and the required safety level 2 3 Technical data Standards IEC 60947 1 Materials Enclosure polyamide PA 6 GF Inspection window polyamide PACM 12 Encapsulation polyurethane 2K PU Labelling plates polycarbonate PC Mechanical data Type of electrical connection Panel jack integrated socket Connection Connectors M12 8 pole A coded Power M12 Power 4 pole T coded IN OUT signals...

Page 3: ...rs 101217788 2 5 m Connecting cable male female connectors 101217789 3 5 m Connecting cable male female connectors 103013428 5 0 m Connecting cable male female connectors 101217790 7 5 m Connecting cable male female connectors 103013429 3 3 2 Colour codes of the Schmersal cables M12 4 pole M12 8 pole PIN Conductor colour PIN Conductor colour 1 BN Brown 1 WH White 2 WH White 2 BN Brown 3 BU Blue 3 ...

Page 4: ... 2 Input LED POWER LED Device connection 3 Input LED POWER LED Device connection 1 Input LED POWER LED Device connection 4 Input LED Connection Power IN Connection Power OUT Power LED fieldbox DIP switch fieldbox configuration Connection Out signals SD and safety signals Park position Jumper 2 Park position Jumper 1 Jumper fieldbox configuration Connection IN signals SD and safety signals ...

Page 5: ...nd 7 8 set Switch 1 2 and 7 8 ON The sealing labels available as an accessory can be used to seal the inspection window after the configuration has been checked 4 5 Connector configuration 4 5 1 Connector configuration of device connection PIN Colour Signal Description of device signals 1 WH A1 24 VDC device supplied 2 BN X1 Safety input 1 3 GN A2 0 VDC device supply 4 YE Y1 Safety output 1 5 GY O...

Page 6: ...DC 10A SD Out 0 VDC 24 VDC SD Out SD In FB 2 3 1 4 I O Power 2 1 3 4 I O SD O N 1 8 7 6 5 4 3 2 BK 4 BN 1 WH 2 WH 2 BU 3 BK 4 BU 3 BN 1 PLC Power supply Safety monitoring module Safety switchgear Fieldbox in the centre JP SW 7 8 OFF 4 devices connected JP SW 1 6 OFF SD Gateway Terminals Optional additional SD line ...

Page 7: ...ive fieldbox EN I O Power 2 1 3 4 I O SD I O Power 2 1 3 4 I O SD O N 1 8 7 6 5 4 3 2 2 1 2 3 1 O N 1 8 7 6 5 4 3 2 Last fieldbox JP SW 7 8 ON 3 devices connected JP SW 5 6 ON Fieldbox in the centre JP SW 7 8 OFF 2 devices connected JP SW 3 4 ON ...

Page 8: ...ly wiring and 10 A fuse protection Use of SCHMERSAL cables The cable lengths listed in the table between power supply and the 1st field box and between fieldboxes are maximum lengths Reducing the individual cable lengths is not critical Device configuration version Max number of devices Equals number of fieldboxes Length of the cable A up to the 1st fieldbox Length of the cables B between the fiel...