![schmersal G50 Operating Instructions Manual Download Page 3](http://html.mh-extra.com/html/schmersal/g50/g50_operating-instructions-manual_1213485003.webp)
3
G50/150
G50-2047
Operating instructions
Gear-switch and safety gear-switch
EN
2.5 Safety classification
Standards:
ISO 13849-1
B
10d
(NC contact):
2,000,000
Service life:
20 years
MTTF
B
d x
x
h
s/h
3600
d
10d
op
op
op
n
0,1 x n
op
t
cycle
(Specifications can vary depending on the application-specific para-
meters h
op
, d
op
and t
cycle
as well as the load.)
3. Mounting
3.1 General mounting instructions
The gear switch can be fixed through flanges with different slotted holes
at the bottom or directly at the front through two M8 threaded holes.
Additionally, rounded flanges are available for frontal fixing.
Please observe the relevant requirements of the standards
ISO 12100 and DIN 56950-1.
3.2 Dimensions
All measurements in mm.
Gear switch
44,4
76,4
54,9
57
20
25
40
62
98
78
68
8,5
88
M20 x 1,5
32,6
114
M8
8
118
80
60
120
200
19
12
h8
10,5
9
Connecting flange 1
7
4
16
24,4
9
96
ø
11
2
ø
85
Connecting flange 2
36,4
2
6
7
145
¤
16
0
¤
14
5
3.3 Switching point setting
During the switching point setting of the contacts, contact
with live parts is possible. Only execute the setting when the
switch lever is not on the switch curve to avoid too strong
a reduction of the lifetime. Always set the emergency limit
switch first.
Standard version
In the standard version, the central screw of the disc cam is loosened.
A disc cam, which can be adjusted over 4° distances, is assigned to
every contact. The disc cams all have gearing as well as a positive
linkage with the worm wheel. After the set-up has been carried out, the
central screw must be firmly retightened.
Standard switching point setting
min. 4°
max. 360°
3.4 Cams and settings
Disc cam with front setting
For the disc cams with front setting (ordering suffix -1600), the dowel of
the disc cam must be pushed in using the screwdriver, which is located
inside the switch (see figure). At the end of the process, the dowel must
autonomously return to the locking position, thus restoring the positive
linkage. The central screw must not be loosened to that effect.
Disc cam with front setting
min. 3.4°
max. 360°
1
2
3
4
F