background image

x.000 / 1

1.2016 / v

.A.   -   101

198433-EN / B / 2016-09-28 / 

AE-Nr

. 5060

EN

Operating instructions. . . . . . . . . . . . .pages 1 to 8

Original

EX-SHGV/EX-SVE/EX-SVM

Operating instructions

EX Trapped key system

EN

1

1.  About this document

1.1  Function

This operating instructions manual provides all the information you 

need for the mounting, set-up and commissioning to ensure the safe 

operation and disassembly of the safety switchgear. The operating 

instructions must be available in a legible condition and a complete 

version in the vicinity of the device.

1.2  Target group: authorised qualified personnel

All operations described in this operating instructions manual must 

be carried out by trained specialist personnel, authorised by the plant 

operator only.

Please make sure that you have read and understood these operating 

instructions and that you know all applicable legislations regarding 

occupational safety and accident prevention prior to installation and 

putting the component into operation.

The machine builder must carefully select the harmonised standards 

to be complied with as well as other technical specifications for the 

selection, mounting and integration of the components.

1.3  Explanation of the symbols used

Information, hint, note:

This symbol is used for identifying useful additional information.

Caution:

 Failure to comply with this warning notice could 

lead to failures or malfunctions.

Warning:

 Failure to comply with this warning notice could 

lead to physical injury and/or damage to the machine.

1.4  Appropriate use

The products described in these operating instructions are developed to 

execute safety-related functions as part of an entire plant or machine. It 

is the responsibility of the manufacturer of a machine or plant to ensure 

the correct functionality of the entire machine or plant.

The safety switchgear must be exclusively used in accordance with 

the versions listed below or for the applications authorised by the 

manufacturer. Detailed information regarding the range of applications 

can be found in the chapter "Product description".

1.5  General safety instructions

The user must observe the safety instructions in this operating 

instructions manual, the country-specific installation standards as well 

as all prevailing safety regulations and accident prevention rules.

Further technical information can be found in the Schmersal 

catalogues or in the online catalogue on the Internet:  

www.schmersal.net.

The information contained in this operating instructions manual is 

provided without liability and is subject to technical modifications. There 

are no residual risks, provided that the safety instructions as well as 

the instructions regarding mounting, commissioning, operation and 

maintenance are observed.

1.6  Warning about misuse

In case of improper use or manipulation of the safety switch-

gear, personal hazards or damages to machinery or plant 

components cannot be excluded when safety switchgear is 

used. The relevant requirements of the standard ISO 14119 

must be observed.

Content

1  About this document

1.1  Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.2 

Target group: authorised qualified personnel

. . . . . . . . . . . . . . . . . .1

1.3  Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.4  Appropriate use  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.5  General safety instructions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.6  Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.7  Exclusion of liability  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2  Product description

2.1  Ordering code  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.2  Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.3  Destination and use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.4  Technical data  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

2.5 

Safety classification

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

3  Mounting

3.1  General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

3.2  Dimensions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

4  Electrical connection

4.1  General information for electrical connection. . . . . . . . . . . . . . . . . .7

4.2  Contact variants. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

5  Set-up and maintenance

5.1  Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

5.2  Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

6  Disassembly and disposal

6.1  Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

6.2  Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

7  EU Declaration of conformity

Summary of Contents for EX-SHGV

Page 1: ...ality of the entire machine or plant The safety switchgear must be exclusively used in accordance with the versions listed below or for the applications authorised by the manufacturer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this operating instructions ma...

Page 2: ...compliance with the Machinery Directive and the Explosion Protection Directive is maintained 2 2 Special versions For special versions which are not listed in the order code below 2 1 these specifications apply accordingly provided that they correspond to the standard version 2 3 Destination and use The trapped key system consisting of the components EX SHGV EX SHGV ESS EX SVE and EX SVM has been ...

Page 3: ... included in delivery to the right 3 so that the solenoid is pulled into the release position The normal locking function is only restored after the triangular key has been returned to its original position 4 The manual release must be sealed after being put into operation e g sealant etc Key distribution station EX SVM1 In position 1 the primary key can be withdrawn When the primary key is remova...

Page 4: ... 14119 EN 13463 1 EN 60079 0 Enclosure cover Aluminium galvanised steel Actuator and locking bolt Stainless steel zinc die cast Coding level according to ISO 14119 low Protection class IP65 Ambient temperature 0 C 70 C Actuating speed 1 m s Actuating frequency max 5 h Mechanical life 100 000 operations Fmax 1 250 N EX SHGV B 1 750 N FZh 950 N EX SHGV B 1 300 N Latching force 5 N Key operated selec...

Page 5: ...are provided for fixing the interlock When used in applications with function for the protection of man the components must be fitted so that disassembly is prevented e g drill out the hexagonal recess of the fixing screws blocking the hexagonal recess using a plastic cone The solenoid interlock must not be used as an end stop Any mounting position The mounting position must be chosen so as to avo...

Page 6: ...31 25 2 31 60 5 5 22 71 103 30 20 40 47 7 5 5 5 1 16 24 22 41 32 3 43 Key operated selector switch EX SHGV ESS21S2 103 60 33 52 60 29 5 46 10 30 key operated selector switch interlocking device EX SVE 130 70 82 72 144 96 60 4 109 60 120 Key distribution station EX SVM1 6 E EX SVM1 10 E 2 9 50 90 45 5 2 9 50 90 45 5 180 162 120 102 240 222 120 102 EX SVM1 6 A EX SVM1 10 A 50 113 5 33 66 120 9 5 6 6...

Page 7: ... 1 Key A Positive break Solenoid connection Enabling circuit solenoid monitoring Enabling circuit key operated selector switch channel 1 Auxiliary contacts key operated selector switch Auxiliary contact solenoid Enabling circuit key operated selector switch channel 2 5 Set up and maintenance 5 1 Functional testing The safety function of the safety components must be tested The following conditions...

Page 8: ...uctions EX Trapped key system EX SHGV EX SVE EX SVM 7 EU Declaration of conformity Name of the component EX SHGV L II 2GD c 85 C X EX SHGV ESS L II 3GD Ex tc IIIC T110 C Dc X Ex ic IIC T5 X EX SVE L II 3D Ex tc IIIC T85 C Dc X EX SVM L II 2GD c 85 C X Type Refer to ordering code Description of the component Interlocking device with electromagnetic interlock for safety functions Relevant Directives...

Reviews: