background image

3

EX-BNS40S

Operating instructions

Safety sensor

EN

3.  Mounting

3.1  General mounting instructions

• Fitting is only authorised in a de-energised condition.

• Do not use the sensor and the actuator as a mechanical backstop.

•  Any mounting position, provided that the active surfaces are opposite.

•  Inseparably fix the sensor and the actuator to the safety guard.

•  Do not install the safety sensor and the actuator in strong magnetic 

fields.

•  If possible, do not mount the sensor and the actuator on 

ferromagnetic material. When the sensor and the actuator are 

installed on ferromagnetic material, variations can be expected in 

the limit distances. The use of a non-magnetic spacer of at least 5 

mm thick must be used. The use of non-magnetic fixing screws is 

recommended also.

•  Do not subject the safety sensor and actuator to extreme vibrations 

and shocks.

•  Keep away from metal chips.

•  The mounting distance between two sensors should always be at 

least 50 mm.

Also suitable for concealed mounting behind non-

ferromagnetic covers.

Safety sensor and actuator must be permanently fitted to  

the safety guards and protected against displacement by 

suitable measures (tamperproof screws, gluing, drilling of  

the screw heads).  

3.2  Dimensions

All measurements in mm.

EX-BNS40S safety sensor

¤4.2

78

88

17.5

27

14.5

7

EX-BNS40S-…-C safety sensor

88

27

14.5

7

78

9.5

M4

BPS40S-1 Actuator

¤4.2

78

88

9.5

27

14.5

BPS40S-2 Actuator

¤4.2

78

88

17.5

27

14.5

BPS40S-1-C Actuator

88

27

14.5

78

9.5

M4

BPS40S-2-C Actuator

88

27

14.5

78

17.5

M4

Summary of Contents for EX-BNS40S

Page 1: ...lity of the entire machine or plant The safety switchgear must be exclusively used in accordance with the versions listed below or for the applications authorised by the manufacturer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this operating instructions man...

Page 2: ... consisting of the safety sensor the actuator and the safety monitoring module meets the requirements of the standard IEC 60947 5 3 The safety sensor is especially suitable for food processing machinery and plants Due to the stainless steel enclosure the safety sensor is resistent to corrosion and cleaning agents The safety sensor is suitable for concealed mounting behind non ferromagnetic covers ...

Page 3: ... magnetic spacer of at least 5 mm thick must be used The use of non magnetic fixing screws is recommended also Do not subject the safety sensor and actuator to extreme vibrations and shocks Keep away from metal chips The mounting distance between two sensors should always be at least 50 mm Also suitable for concealed mounting behind non ferromagnetic covers Safety sensor and actuator must be perma...

Page 4: ...ices that do not require an earth connection 4 2 Contact variants The contact position shows the actuated sensor function when the safety guard is closed For safety sensors with LED the LED is illuminated when the safety guard is closed The contact configurations of the versions with or without LED are identical S14PK GNS21 GYS13 WHS31 S22YE S32BN 4 3 Connection The safety sensor is suitable for u...

Page 5: ...ance 5 1 Functional testing The safety function of the safety components must be tested The following conditions must be previously checked and met 1 Fitting of the sensor and the actuator 2 Fitting and integrity of the power cable 3 The system is free of dirt and soiling in particular metal chips 5 2 Maintenance In the case of correct installation and adequate use the safety sensor features maint...

Page 6: ...ed to in Appendix IV 2014 34 EU TÜV Rheinland Industrie Service GmbH Am Grauen Stein 51105 Köln ID n 0035 Person authorised for the compilation of the technical documentation Oliver Wacker Möddinghofe 30 42279 Wuppertal Place and date of issue Wuppertal September 11 2017 Authorised signature Philip Schmersal Managing Director EU Declaration of conformity Original K A Schmersal GmbH Co KG Möddingho...

Reviews: