schmersal CSS 8-180 Operating Instructions Manual Download Page 10

10

EN

CSS180-F-EN

Operating instructions

Safety sensor

CSS 8-180

9.  EU Declaration of conformity

Name of the component:

CSS 8-180

Type:

See ordering code

Description of the component:

Non-contact safety sensor

Relevant Directives:

2006/42/EG

2014/30/EU

2011/65/EU

Machinery Directive

EMC-Directive

RoHS-Directive

Applied standards:

DIN EN 60947-5-3:2014,

DIN EN ISO 14119:2014,

DIN EN ISO 13849-1:2008,

DIN EN 61508:2011 

Notified body for the prototype test:

Institut für Arbeitsschutz der  

Deutschen Gesetzlichen Unfallversicherung

Alte Heerstraße 111

53757 Sankt Augustin

ID n°: 0121

EC-prototype test certificate:

IFA 1001232

Person authorised for the compilation  

of the technical documentation:

Oliver Wacker

Möddinghofe 30

42279 Wuppertal

Place and date of issue:

Wuppertal, February 3, 2017

Authorised signature

Philip Schmersal

Managing Director

EU Declaration of conformity

Original

K.A. Schmersal GmbH & Co. KG

Möddinghofe 30

42279 Wuppertal

Germany

Internet: www.schmersal.com

We hereby certify that the hereafter described components both in their basic design and construction conform 

to the applicable European Directives. 

The currently valid declaration of conformity can be  

downloaded from the internet at www.schmersal.net.

K.A. Schmersal GmbH & Co. KG

Möddinghofe 30, 42279 Wuppertal

Germany

Phone:  +49 202 6474-0

Telefax:  +49 202 6474-100

E-Mail: [email protected]

Internet:   www.schmersal.com

Summary of Contents for CSS 8-180

Page 1: ...ised by the manufacturer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this operating instructions manual the country specific installation standards as well as all prevailing safety regulations and accident prevention rules Further technical information can b...

Page 2: ...tion the safety sensor monitors the position of hinged sliding or removable safety guards by means of the coded electronic CST 180 1 or CST 180 2 actuators Mode of operation of the safety outputs The opening of a safety guard i e the actuator is removed out of the active zone of the safety sensor will immediately disable the safety outputs also refer to Switching distance of the safety sensor Seri...

Page 3: ...unted in any position The only condition is that the active surface of the safety sensor and the actuator are opposite The sensor enclosure must not be used as an end stop The safety sensor must only be used within the assured switching distances sao and sar The safety sensor and the corresponding actuator can be fixed using the supplied M18 nuts A F 24 The max tightening torque of the supplied sc...

Page 4: ...ly lit yellow In this position a reliable switching position of the sensor is obtained also refer to Operating Principle of the Diagnostic Outputs The proper functionality must always be checked by means of the connected safety monitoring module 3 4 Switch distance The graphs show the switch on and switch off points of the sensor due to the approach of the actuator The maximum misalignment of the ...

Page 5: ...necting cables must be taken as large as possible Wiring examples for series wiring refer to appendix 4 3 Note on the total length of a safety sensor chain The voltage drop of a long sensor chain must be taken into account when planning the wiring Typical resistance of the different sensor connecting cables 20 C 0 50 mm2 approx 36 Ω km 0 34 mm2 approx 52 Ω km 0 25 mm2 approx 71 Ω km The resistance...

Page 6: ... a safety related output The diagnostic output can also be used to detect clearance variations between the sensor and the actuator in the same way as the yellow LED An active fault causes the diagnostic output to be disabled The safety outputs are disabled after max 30 minutes if the fault is not rectified The signal combination diagnostic output disabled and safety channels still enabled can be u...

Page 7: ...nsor and so on A 200m long sensor chain can be set up A safety sensor of the CSS 8 180 2P Y L type can also be used as a terminal device in a chain in this situation additional wiring is required The positive operating voltage must be wired to both safety inputs Wiring example 2 Safety monitoring module 24V 0V GY BN BU WH VT BK WH 0V WH VT 0V GY BK RD 0V WH VT 0V BN BU BN BU BN BU GY BK RD GY BK R...

Page 8: ... cable with connector Inputs IN female connector M12 4 pole 0 25 m Outputs OUT male connector M12 4 pole 2 m 3 2 5 1 4 3 2 5 1 4 Female connector IN Male connector OUT Lead colours connecting cable Wiring grey cable IN Black cable OUT Pin configuration of the connector BN brown A1 Ue A1 Ue Pin 1 BU blue A2 GND A2 GND Pin 3 BK black X1 safety input 1 Y1 safety output 1 Pin 4 WH white X2 safety inpu...

Page 9: ...X1 Safety input 1 2 BN WH WH A2 GND 3 GN BU BU Y1 Safety output 1 4 YE BK BK OUT Diagnostic output 5 GY GY GY X2 Safety input 2 6 PK VT PK Y2 Safety output 2 7 BU RD VT IN without function 8 RD PK OR Colour code key Code Colour Code Colour Code Colour Code Colour BK black GN green PK pink WH white BN brown GY grey RD red YE yellow BU blue OR orange VT violet Connecting cables with coupling female ...

Page 10: ...est certificate IFA 1001232 Person authorised for the compilation of the technical documentation Oliver Wacker Möddinghofe 30 42279 Wuppertal Place and date of issue Wuppertal February 3 2017 Authorised signature Philip Schmersal Managing Director EU Declaration of conformity Original K A Schmersal GmbH Co KG Möddinghofe 30 42279 Wuppertal Germany Internet www schmersal com We hereby certify that ...

Reviews: