5
BNS 36
Operating instructions
Safety sensor
EN
4.3 Connector plug
Connector plug
3
1
4
2
6
4
3
2
5
1
M8, 4-pole,
with screw terminal or snap fitting
8 mm, 6-pole,
with snap fitting
Accessories: connecting cable with coupling
M8, 4-pole, with screw terminal 2 m
5 m
10 m
3
1
4
2
1 BN
straight
101209947 101209981 -
2 WH
3 BU
angled
101210557 101210559 -
4 BK
8 mm, 6-pole, with snap fitting 2 m
5 m
10 m
6
4
3
2
5
1
1 GN
straight
101206010 101206011 101206012
2 YE
3 GY
4 PK
angled
101206013 101206014 101206015
5 WH
6 BN
Accessory: Y-adapter BNS-Y-11
S21
S22
S13
S14
1
3
2
4
1
3
2
4
BNS-Y-11
AES
SRB
BNS 33-11Z
1
2
3
4
BNS 36-11Z
Accessory: Y-adapter BNS-Y-02
1
3
2
4
1
3
2
4
1
2
3
4
AES
SRB
BNS 260-02z
BNS-Y-02
S21
S22
S11
S12
BNS 36-02Z
5. Set-up and maintenance
5.1 Functional testing
The safety function of the safety sensor must be tested. The following
conditions must be previously checked and met:
1. Fitting of the sensor and the actuator.
2. Fitting and integrity of the power cable.
3. The system is free of dirt and soiling
(in particular metal chips).
5.2 Maintenance
In the case of correct installation and adequate use, the safety sensor
features maintenance-free functionality.
A regular visual inspection and functional test, including the following
steps, is recommended:
• Check of the safety function
• Check the fitting of the sensor and the actuator.
• Remove possible metal chips.
• Check the cable for damage.
Adequate measures must be taken to ensure protection
against tampering either to prevent tampering of the safety
guard, for instance by means of replacement actuators.
Damaged or defective components must be replaced.
6. Disassembly and disposal
6.1 Disassembly
The safety sensor must be disassembled in de-energised
condition only.
6.2 Disposal
The safety sensor must be disposed of in an appropriate manner in