background image

9

EN

BDF200-SD_FB-C-EN

BDF200-SD

BDF200-FB

Operating instructions

Control panel with emergency stop

10. 

EU Declaration of conformity

Place and date of issue:

Wuppertal, August 31, 2018

Authorised signature

Philip Schmersal

Managing Director

EU Declaration of conformity

Original

KA Schmersal GmbH & Co KG

Möddinghofe 30

42279 Wuppertal

Germany

Internet: wwwschmersalcom

We hereby certify that the hereafter described components both in their basic design and construction conform 

to the applicable European Directives 

Name of the component:

BDF200-SD

BDF200-FB

Type:

See ordering code

Description of the component:

Control panel with emergency stop and  

integrated SD interface or FB interface

Relevant Directives:

2006/42/EG

2014/30/EU

2011/65/EU

Machinery Directive

EMC-Directive

RoHS-Directive

Applied standards:

IEC 60947-5-5:2016

EN ISO 13849-1:2015

IEC 61508 parts 1-7:2010

EN 62061:2005 + AC:2010 + A1:2013 + A2:2015

Notified body for the prototype test:

TÜV Rheinland Industrie Service GmbH

Alboinstr 56

12103 Berlin

ID n°: 0035

EC- test certificate:

01/205/561300/17

Person authorised for the compilation  

of the technical documentation:

Oliver Wacker

Möddinghofe 30

42279 Wuppertal

The currently valid declaration of conformity can be  

downloaded from the internet at wwwschmersalnet

Summary of Contents for BDF200-FB

Page 1: ...version in the vicinity of the device 1 2 Target group authorised qualified personnel All operations described in this operating instructions manual must be carried out by trained specialist personne...

Page 2: ...ained selector switch 2 or 3 positions WT 2 3 Maintained spring return rotary selector switch 2 or 3 positions SWS SWT 20 Key operated selector switch 2 positions Pos 4 Command and signalling device L...

Page 3: ...urce has to be an isolated secondary source limited by a Listed fuse rated 4A min 24VAC DC Adapters providing field wiring means are available from the manufacturer Refer to manufacturer s information...

Page 4: ...e rating of a device chain for protection of the cable depends on the cross section of the cables used Requirements for the connected safety monitoring module Dual channel safety input suitable for p...

Page 5: ...n of the command and signalling devices The non safety signals of the command devices are transmitted to the control system via the response byte in the SD FB protocol The Illuminated signals are cont...

Page 6: ...ges are not transferred Table 1 Overview of status signals warnings or error messages of SD variant Communication directions Request byte From PLC to local safety switchgear Response byte From local s...

Page 7: ...K BK OUT SD output 5 GY GY GY X2 Safety input 2 6 PK VT PK Y2 Safety output 2 7 BU RD VT IN SD input 8 RD PK OR Connector plug M12 8 pole A coded 9 2 Pin assignment FB variant Function safety switchge...

Page 8: ...ED illuminated push button pos 4 Bit 6 Bit 7 Error reset PLC input data BDF200 FB BDF200 FB SFB PLC Device module SFB module data_1 Sub module Diagnosis and FB interface 6 byte input Slot PROFINET Eth...

Page 9: ...BDF200 SD BDF200 FB Type See ordering code Description of the component Control panel with emergency stop and integrated SD interface or FB interface Relevant Directives 2006 42 EG 2014 30 EU 2011 65...

Page 10: ...A Schmersal GmbH Co KG M ddinghofe 30 D 42279 Wuppertal Postfach 24 02 63 D 42232 Wuppertal Phone 49 0 2 02 64 74 0 Telefax 49 0 2 02 64 74 1 00 E Mail info schmersal com Internet http www schmersal c...

Reviews: