Operating instructions
Safety-monitoring module

AZR 31S1

EN

There are no residual risks, provided that the safety instructions as well 
as the instructions regarding mounting, commissioning, operation and 
maintenance are observed.

1.6  Warning about misuse

In case of improper use or manipulation of the safety switch-
gear, personal hazards or damages to machinery or plant 
components cannot be excluded. The relevant requirements 
of the standards EN 1088 and EN ISO 13850 must be  
observed.

1.7  Exclusion of liability

We shall accept no liability for damages and malfunctions resulting from 
defective mounting or failure to comply with this operating instructions 
manual. The manufacturer shall accept no liability for damages result-
ing from the use of unauthorised spare parts or accessories.

For safety reasons, invasive work on the device as well as arbitrary re-
pairs, conversions and modifications to the device are strictly forbidden; 
the manufacturer shall accept no liability for damages resulting from 
such invasive work, arbitrary repairs, conversions and/or modifications 
to the device.

The safety-monitoring module must only be used when the enclosure is 
closed, i.e. with the front cover fitted.

2.  Product description

2.1  Ordering code

This operating instructions manual applies to the following types:

AZR 31S1 

 

No.

Option

Description

230VAC

230 VAC

115VAC

115 VAC

24VAC

24 VAC

24 VDC

24 VDC

Pull-in delay 7 sec.

2 sec.

Pull-in delay 2 sec.

This device is designed as dual-channel fail-safe standstill 
monitor for monitoring the sensorless motor standstill (no 
adjustment required). The nominal motor voltage may amount 
up to 400 VAC ±10%.

Only if the information described in this operating instructions 
manual are realised correctly, the safety function and therefore 
the compliance with the Machinery Directive is maintained.

2.2  Special versions

For special versions, which are not listed in the order code below 2.1, 
these specifications apply accordingly, provided that they correspond to 
the standard version.

2.3  Destination and use

The safety-monitoring modules for integration in safety circuits are 
designed for fitting in control cabinets. They are used for the safe evalu-
ation of the voltage at the inputs L1, L2 and L3

The safety function is defined as the opening of the enabling contacts 
13-14, 23-24 and 33-34 when voltage is detected at the inputs L1, L2 
and L3. The safety-relevant current paths with the output contacts  
13-14, 23-24 and 33-34 meet the following requirements under  
observation of a B

10d 

value assessment (also refer to "Requirements  

to DIN EN ISO 13849-1"): 
– control category 4 – PL e to DIN EN ISO 13849-1 
– corresponds to SIL 3 to DIN EN 61508-2 
–  corresponds to SILCL 3 to DIN EN 62061 

(corresponds to control category 4 to DIN EN 954-1)

To determine the Performance Level (PL) of the entire safety function 
(e.g. sensor, logic, actuator) to DIN EN ISO 13849-1, an analysis of all 
relevant components is required.

2.4  Technical data

General data 

Standards:

 

IEC / EN 60204-1, EN 60947-5-1;  

EN ISO 13849-1, IEC / EN 61508

Climate resistance:

 

EN 60068-2-78

Mounting:

 

Snaps onto standard DIN rail to EN 60715

Terminal designations:

 

EN 60947-1

Material of the housings:

 

glass-fibre reinforced  

thermoplastic, ventilated

Material of the contacts:

 

AgSnO, self-cleaning, positive drive

Weight:

 

115/230 V-version: typ. 400 g 

24 V-version: typ. 380 g

Start conditions:

 Automatic

Feedback circuit (Y/N):

 yes

Pull-in delay: 

 

typ. 7 sec. after the detection of the standstill 

(2 sec. variants: after typ. 2 sec.)

Drop-out delay:

  

immediately after the detection  

of a rotary movement < 15 ms

Mechanical data 

Connection type:

 

Screw connection

Cable section:

  

min. 0.25 mm² / max. 2.5 mm²

Connecting cable:

 

rigid or flexible

Tightening torque for the terminals: 

 

0.6 Nm

With removable terminals (Y/N):

 Nein

Mechanical life:

 

10 million operations

Electrical life: 

 

Derating curve available on request

Resistance to shock:

 

10 g / 11 ms

Resistance to vibrations to EN 60068-2-6:

 

10 … 55 Hz,  

amplitude 0.35 mm

Ambient conditions 

Ambient temperature:

 

–25 °C … +45 °C

Storage and transport temperature:

 

–40 °C … +85 °C

Protection class:

 

Enclosure: IP40  

Terminals: IP20  

Clearance: IP54

Air clearances and creepage distances 

  

to IEC/EN 60664-1:

 

4 kV/2 (basic insulation)

EMC rating: 

 

to EMC Directive

Electrical data 

Contact resistance in new state: 

 

max. 100 mΩ

Power consumption:

 

max. 3.2 W / 4 VA

Rated operating voltage U

e

:

 

115 VAC / 230 VAC: –15% / +10% 

24 VAC / VDC: –15% / +20%,  

residual ripple max. 10%

Frequency range:

 

50 Hz / 60 Hz (AC-operating voltage)

Fuse rating for the operating    
voltage (F1):

 

230 VAC-version: T 32 mA / 250 V 

 

115 VAC-version: T 64 mA / 250 V 

 

24 VAC / VDC-version: T 315 mA / 250 V