AZM 200D

Operating instructions

Safety switch with interlocking function

EN

Diagnostic output OUT:

 

short-circuit proof, p-type

Rated operating voltage U

e2

:

 

0 V ... 4 V under U

e

Operating current I

e2

:

 

max. 0.1 A*

Utilisation category:

 

DC-13: 24 V / 0.05 A

*  Residual current through outputs  

 

Y3, Y4, OUT:

 

I

Y3

 + I

Y4

 + I

OUT

 ≤ 0.1 A

Magnet control IN:

 

Rated operating voltage U

e4

/

Low

:

 

−3 V ... 5 V

Rated operating voltage U

e4

/

High

:

 

15 V ... 30 V

Rated operating current l

e4

:

 

typically 10 mA at 24 V, 

 dynamically 20 mA

Magnet:

 

100% ED

2.5  Safety classification

Safety guard monitoring, Y1 and Y2

Standards:

 

EN ISO 13849-1, IEC 61508,  

IEC 60947-5-3

PL:

 

up to e

Control category:

 

up to 4

PFH value:

 

4 x 10

-9 

/ h

SIL:

 

up to 3

Service life:

 

20 years

Classification:

 PDF-M

Locking monitoring, Y3 and Y4

Standards:

 

EN ISO 13849-1, IEC 61508,  

IEC 60947-5-3

PL:

 

up to d

Control category:

 

up to 3

PFH value:

 

1 x 10

-7 

/ h

SIL:

 

up to 2

Service life:

 

20 years

Classification:

 PDF-M

3.  Mounting

3.1  General mounting instructions

For fitting the safety switch and the actuator, two mounting holes for M6 

screws with washers (washers included in delivery) are provided.  The 

safety switch must not be used as end stop. Any mounting position. 

The mounting position however must be chosen so that the ingress of 

dirt and soiling in the used opening is avoided. The unused actuator 

opening must be sealed by means of the dust-proof flap (included in 

delivery).

Please observe the remarks of the standards EN ISO 12100, 

EN 953 and EN 1088.

The constructor must provide for the necessary strain relief 

of the connections.

Admissible mounting set-up

Inadmissible mounting set-up

Mounting of the actuators and the safety switches

Refer to the mounting instructions manual for the corresponding 

actuator.

3.2  Dimensions

All measurements in mm.

40

220

155,5

5

6,5

32,5

38

7,5

M20x1,5

3,3

GN

RD

YE

20 1

±

A

B

Key

A: Manual release

B: Cable entry

Manual release

For the machine set-up, the safety switch can be unlocked in de-

energised condition. After opening of the plastic flap "A" (refer to image 

"Dimensions"), the triangular key must be turned clockwise to bring 

the blocking bolt in unlocking condition. The normal locking function is 

only restored after the triangular key has been returned to its original 

position. Caution: do not turn beyond the latching point! After being 

put into operation, the manual release must be secured by closing the 

plastic flap "A" and affixing the seal, which is included in delivery.

Component ready  

for operation

Component not ready  

for operation

Summary of Contents for AZM 200D

Page 1: ...re machine or plant The safety switchgear must be exclusively used in accordance with the versions listed below or for the applications authorised by the manufacturer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this operating instructions manual the country ...

Page 2: ...control category 3 or opened PL e control category 4 and maintaining the safe switched off condition of the safety outputs for as long as the safety guard is open Interlocks with power to lock principle may only be used in special cases after a thorough evaluation of the accident risk since the safety guard can be opened immediately on failure of the power supply or upon activation of the main swi...

Page 3: ... Any mounting position The mounting position however must be chosen so that the ingress of dirt and soiling in the used opening is avoided The unused actuator opening must be sealed by means of the dust proof flap included in delivery Please observe the remarks of the standards EN ISO 12100 EN 953 and EN 1088 The constructor must provide for the necessary strain relief of the connections Admissibl...

Page 4: ...rol In the power to unlock version of the AZM 200 the safety switch is unlocked when the IN signal 24V is set In the power to lock version of the AZM 200 the safety switch is locked when the IN signal 24 V is set 5 1 Safety switch with diagnostic output Mode of operation of the safety outputs The unlocking of the safety switch causes the safety outputs Y3 and Y4 to be disabled As long as the actua...

Page 5: ...f On 24 V 24 V 24 V 0 V 24 V Error warning1 solenoid interlock locked 0 V 24 V On Flashes 2 On 24 V1 24 V1 24 V 0 V 0 V Error 0 V 24 V 24 V 0 V On Flashes 2 Off 0 V 0 V 24 V 0 V 0 V 1 after 30 min disabling due to fault 2 refer to flash code Table 2 flash codes red LED Flash codes red Designation Autonomous switch off after Error cause 1 flash pulse Error warning at output Y1 30 min Fault in outpu...

Page 6: ...tor 2 Remove particles of dust and soiling 3 Check cable entry and connections Damaged or defective components must be replaced 7 Disassembly and disposal 7 1 Disassembly The safety switchgear must be disassembled in a de energised condition only 7 2 Disposal The safety switchgear must be disposed of in an appropriate manner in accordance with the national prescriptions and legislations 8 Appendix...

Page 7: ...trol 8 PK 8 OR shielded RD LED LED 9 9 Button Input output 10 10 Button Input output 11 11 NC 12 12 Connector plug ST1 M23 8 1 pole Connector plug ST2 M12 8 pole Connector plug ST3 M23 12 pole 1 2 9 3 4 5 6 7 8 5 8 4 3 2 1 7 6 10 12 11 9 8 7 6 5 4 3 2 1 Connecting cables with female connector IP67 M23 8 1 pole 8 x 0 75 mm Connecting cables with female connector IP67 M12 8 pole 8 x 0 23 mm Connecti...

Page 8: ...ions Relevant Directives Machinery Directive EMC Directive RoHS Directive 2006 42 EC 2014 30 EU 2011 65 EU Applied standards EN 60947 5 1 2004 AC 2005 A1 2009 EN 60947 5 3 2013 ISO 14119 2013 EN ISO 13849 1 2008 AC 2009 EN 61508 Teile 1 7 2010 EN 62061 2005 AC 2010 A1 2013 Notified body for the prototype test TÜV Rheinland Industrie Service GmbH Alboinstr 56 12103 Berlin ID n 0035 EC prototype tes...

Reviews: