Operating instructions

Solenoid interlock

9.  EU Declaration of conformity

Name of the component:

AZM 200 AS

Type:

See ordering code

Description of the component:

Interlocking device with electromagnetic  

interlock for safety functions with  

integrated AS-i Safety at Work

Relevant Directives:

Machinery Directive

EMC-Directive

RoHS-Directive

2006/42/EC

2014/30/EU

2011/65/EU

Applied standards:

EN 60947-5-1:2004 + AC:2005 + A1:2009,

EN 60947-5-3:2013,

ISO 14119:2013,

EN ISO 13849-1:2008 + AC:2009,

EN 61508 parts 1-7:2010,

EN 62061: 2005 + AC:2010 + A1:2013

Notified body for the prototype test:

TÜV Rheinland Industrie Service GmbH

Alboinstr. 56, 12103 Berlin

ID n°: 0035

EC-prototype test certificate:

01/205/5122.01/15

Person authorised for the compilation  

of the technical documentation:

Oliver Wacker

Möddinghofe 30

42279 Wuppertal

The currently valid declaration of conformity can be  

downloaded from the internet at www.schmersal.net.

Place and date of issue:

Wuppertal, May 25, 2016

Authorised signature

Philip Schmersal

Managing Director

EU Declaration of conformity

Original

K.A. Schmersal GmbH & Co. KG

Möddinghofe 30

42279 Wuppertal

Germany

Internet: www.schmersal.com

We hereby certify that the hereafter described components both in their basic design and construction conform 

to the applicable European Directives. 

Summary of Contents for AZM 200 AS

Page 1: ...the manufacturer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions...

Page 2: ...is a safety switch with an interlock function for process protection The safety function consists of safely switching off the code transfer when the guard system is unlocked or opened and maintaining...

Page 3: ...rin ciple of isolating the supply of power to the solenoid The safety classification for the release function only applies to devices with monitored interlock function in power to unlock version and w...

Page 4: ...uts of the AS i safety monitor are enabled when the following conditions are met guard door detected the actuator is inserted AZM 200 BZ ST T AS The safety outputs of the AS i safety monitor are only...

Page 5: ...cyclically queried by the control system through the AS i master To that effect the 4 input bits with the varying SaW code of a Safety at Work slave are evaluated through an OR operation with 4 inputs...

Page 6: ...be observed refer to error warning switch off after 30 min 7 Set up and maintenance 7 1 Functional testing The safety function of the safety components must be tested The following conditions must be...

Page 7: ...2013 Notified body for the prototype test T V Rheinland Industrie Service GmbH Alboinstr 56 12103 Berlin ID n 0035 EC prototype test certificate 01 205 5122 01 15 Person authorised for the compilatio...

Page 8: ...K A Schmersal GmbH Co KG M ddinghofe 30 42279 Wuppertal Germany Phone 49 202 6474 0 Telefax 49 202 6474 100 E Mail info schmersal com Internet www schmersal com...

Reviews: