schmersal AZ 3350 Operating Instructions Download Page 2

2

Operating instructions

Safety switch

AZ 3350

EN

1.7  Exclusion of liability

We shall accept no liability for damages and malfunctions resulting from 

defective mounting or failure to comply with this operating instructions 

manual. The manufacturer shall accept no liability for damages result-

ing from the use of unauthorised spare parts or accessories.

For safety reasons, invasive work on the device as well as arbitrary re-

pairs, conversions and modifications to the device are strictly forbidden; 

the manufacturer shall accept no liability for damages resulting from 

such invasive work, arbitrary repairs, conversions and/or modifications 

to the device.

2.  Product description

2.1  Ordering code

This operating instructions manual applies to the following types:

AZ 3350-

-

-

No. Option

Description

03-ZK

3 NC

12-ZUEK

1 NO / 2 NC

U90

Actuating head can be rotated 90°  

for door hinge left

U270

Actuating head can be rotated 270°  

for door hinge right

1637

Gold-plated contacts

Actuator

- for sliding safety guards:

AZ 3350-B1

Straight actuator with rubber mounting

AZ 3350-B5

Angled actuator with rubber mounting

- for hinged safety guards:

AZ 3350-B1R

Flexible actuator with rubber mounting

AZ 3350-B5R

Angled actuator with rubber mounting

AZ 3350-B6

Flexible actuator with through-holes

AZ 3350-B6H

Flexible actuator with threaded holes, front side

- in combination with AZ 3350...-U90 or U270:

STS 30-01...08

Safety door-handle system  

for hinged safety guards

Only if the information described in this operating instructions 

manual are realised correctly, the safety function and therefore 

the compliance with the Machinery Directive is maintained.

2.2  Special versions

For special versions, which are not listed in the order code below 2.1, 

these specifications apply accordingly, provided that they correspond to 

the standard version.

2.3  Destination and use

The safety switches are suitable for sliding, hinged or removable safety 

guards, which need to be closed in order to ensure the necessary 

operational safety.

The safety switches are used for applications, in which the hazardous 

situation is terminated without delay when the safety guard is opened.

The safety switchgears are classified according to  

ISO 14119 as type 2 interlocking devices.

The user must evaluate and design the safety chain in 

 accordance with the relevant standards and the required 

safety level.

The entire concept of the control system, in which the safety 

component is integrated, must be validated to the relevant 

standards.

2.4  Technical data

Standards:

 

IEC 60947-5-1, BG-GS-ET-15

Enclosure:

 

light-alloy diecast, paint finish

Coding level according to ISO 14119:

 low

Protection class:

 IP67 

Contact material:

 Silver

Contact type:

 

change-over with double break Zb,  

or 3 NC contacts, galvanically  

separated contact bridges

Switching system:

 

A

 IEC 60947-5-1; slow action,  

NC contact with positive break

Connection:

 

screw terminals

Cable section:

 

min. 0.75 mm², max. 2.5 mm²  

(including conductor ferrules)

Cable entry:

 

M20 x 1.5

Rated impulse withstand voltage U

imp

:

 

4 kV

Rated insulation voltage U

i

:

 

250 V

Thermal test current I

the

:

 

10 A

Utilisation category:

 

AC-15, DC-13

Rated operating current/voltage I

e

/U

e

:

 

4 A / 230 VAC 

4 A / 24 VDC

Required short-circuit current:

 

1000 A

Max. fuse rating:

 

6 A gG D-fuse

Positive break travel: 

 

10.7 mm

Positive break force:

 

each NC contact 5 N

Ambient temperature:

 

–30 °C … +90 °C

Actuating speed:

 

max. 0.2 ms

Actuating frequency:

 

max. 1200/h

Mechanical life:

 

> 1 million operations

2.5  Safety classification

Standards:

 

ISO 13849-1

Envisaged structure: 

 

- Basically:

 

applicable up to Cat. 1 / PL c 

-  With 2-channel usage and  

 

fault exclusion mechanism*:

 

applicable up to Cat. 3 / PL d  

with suitable logic unit

B

10d

 NC contact:

 2,000,000

B

10d

 NO contact at 10% ohmic contact load:

 1,000,000

Service life:

 

20 years

* If a fault exclusion to the 1-channel mechanics is authorised.

MTTF

B

d x

x

h

s/h

3600

d

10d

op

op

op

n

0,1 x n

op

t

cycle

(Determined values can vary depending on the application-specific 

parameters h

op

, d

op

 and t

cycle

 as well as the load.)

If multiple safety components are wired in series, the Performance  

Level to ISO 13849-1 will be reduced due to the restricted error  

detection under certain circumstances.

Summary of Contents for AZ 3350

Page 1: ...for the applications authorised by the manufacturer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this operating instructions manual the country specific installation standards as well as all prevailing safety regulations and accident prevention rules Further ...

Page 2: ...y operational safety The safety switches are used for applications in which the hazardous situation is terminated without delay when the safety guard is opened The safety switchgears are classified according to ISO 14119 as type 2 interlocking devices The user must evaluate and design the safety chain in accordance with the relevant standards and the required safety level The entire concept of the...

Page 3: ...d personnel in a de energised condition The contact labelling can be found in the wiring compartment of the switch Appropriate cable glands with a suitable degree of protection are to be used After wiring dust and soiling must be removed from the wiring compartment 4 2 Contact variants Contacts are shown with safety guard closed 1 NO 2 NC 3 NC 13 21 31 14 22 32 11 21 31 12 22 32 5 Set up and maint...

Page 4: ... Germany Internet www schmersal com We hereby certify that the hereafter described components both in their basic design and construction conform to the applicable European Directives Name of the component AZ 3350 Type See ordering code Description of the component Positive break position switch with separate actuator for safety functions Relevant Directives Machinery Directive RoHS Directive 2006...

Reviews: