schmersal AZ 17-11ZK Operating Instructions Download Page 1

AZ 17

Operating instructions
Safety switch

EN

1

1.  About this document

1.1  Function

This operating instructions manual provides all the information you 
need for the mounting, set-up and commissioning to ensure the safe 
operation and disassembly of the safety switchgear. The operating inst-
ructions must be available in a legible condition and a complete version 
in the vicinity of the device.

1.2  Target group: authorised qualified personnel

All operations described in this operating instructions manual must 
be carried out by trained specialist personnel, authorised by the plant 
operator only.

Please make sure that you have read and understood these operating 
instructions and that you know all applicable legislations regarding 
occupational safety and accident prevention prior to installation and 
putting the component into operation.

The machine builder must carefully select the harmonised standards 
to be complied with as well as other technical specifications for the 
 selection, mounting and integration of the components.

1.3  Explanation of the symbols used

Information, hint, note:

This symbol is used for identifying useful additional information.

Caution:

 Failure to comply with this warning notice could 

lead to failures or malfunctions.

Warning:

 Failure to comply with this warning notice could 

lead to physical injury and/or damage to the machine.

1.4  Appropriate use

The products described in these operating instructions are developed to 
execute safety-related functions as part of an entire plant or machine. It 
is the responsibility of the manufacturer of a machine or plant to ensure 
the correct functionality of the entire machine or plant.

The safety switchgear must be exclusively used in accordance with 
the versions listed below or for the applications authorised by the 
 manufacturer. Detailed information regarding the range of applications 
can be found in the chapter "Product description".

1.5  General safety instructions

The user must observe the safety instructions in this operating 
 instructions manual, the country-specific installation standards as well 
as all prevailing safety regulations and accident prevention rules.

Further technical information can be found in the Schmersal 
catalogues or in the online catalogue on the Internet:  
www.schmersal.net.

The information contained in this operating instructions manual is 
 provided without liability and is subject to technical modifications.

There are no residual risks, provided that the safety instructions as well 
as the instructions regarding mounting, commissioning, operation and 
maintenance are observed.

1.6  Warning about misuse

In case of improper use or manipulation of the safety switch-
gear, personal hazards or damages to machinery or plant 
components cannot be excluded when safety switchgear is 
used. The relevant requirements of the standard ISO 14119 
must be observed.

Content

About this document

1.1  Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.2 

Target group: authorised qualiied personnel

. . . . . . . . . . . . . . . . . . 1

1.3  Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
1.4  Appropriate use  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.5  General safety instructions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.6  Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.7  Exclusion of liability  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

Product description

2.1  Ordering code  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.2  Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.3  Destination and use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.4  Technical data  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.5 

Safety classiication

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

Mounting

3.1  General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
3.2  Dimensions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

Electrical connection

4.1  General information for electrical connection. . . . . . . . . . . . . . . . . . 3
4.2  Contact variants . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

Set-up and maintenance

5.1  Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
5.2  Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

Disassembly and disposal

6.1  Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
6.2  Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

EU Declaration of conformity

x.000 / 04.2016 / v

.A.   -   101

122006-EN / P

 / 2016-03-15 / 

AE-Nr

. 5874

EN

Operating instructions. . . . . . . . . . . . .pages 1 to 4

Original

Summary of Contents for AZ 17-11ZK

Page 1: ...ns listed below or for the applications authorised by the manufacturer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this operating instructions manual the country specific installation standards as well as all prevailing safety regulations and accident preven...

Page 2: ...ards IEC 60947 5 1 BG GS ET 15 Enclosure glass fibre reinforced thermo plastic self extinguishing Actuator stainless steel 1 4301 Coding level according to ISO 14119 low Protection class IP67 to IEC 60529 Contact material Silver Contact type change over with double break Zb or 2 NC contacts galvanically separated contact bridges Switching system A acc IEC 60947 5 1 slow action NC contact with posi...

Page 3: ...cable rearside AZ 17 11ZK 2243 1 AZ 17 11ZRK 2243 1 AZ 17 02ZK 2243 1 AZ 17 02ZRK 2243 1 GY 13 BU 21 14 BK 22 BN GY 11 BU 21 12 BK 22 BN with connector A coding AZ 17 11ZK ST AZ 17 11ZRK ST AZ 17 02ZK ST AZ 17 02ZRK ST 1 2 3 4 21 13 22 14 1 2 3 4 21 11 22 12 5 Set up and maintenance 5 1 Functional testing The safety function of the safety components must be tested The following conditions must be ...

Page 4: ...ertal K A Schmersal GmbH Co KG Möddinghofe 30 D 42279 Wuppertal Postfach 24 02 63 D 42232 Wuppertal Phone 49 0 2 02 64 74 0 Telefax 49 0 2 02 64 74 1 00 E Mail info schmersal com Internet http www schmersal com Place and date of issue Wuppertal March 14 2016 Authorised signature Philip Schmersal Managing Director EU Declaration of conformity Original K A Schmersal GmbH Co KG Möddinghofe 30 42279 W...

Reviews: