background image

AES 2285

Operating instructions

Safety-monitoring module

EN

1

1.  About this document

1.1  Function

This operating instructions manual provides all the information you 

need for the mounting, set-up and commissioning to ensure the safe 

operation and disassembly of the safety-monitoring module. The 

operating instructions must be available in a legible condition and a 

complete version in the vicinity of the device.

1.2  Target group: authorised qualified personnel

All operations described in this operating instructions manual must 

be carried out by trained specialist personnel, authorised by the plant 

operator only.

Please make sure that you have read and understood these operating 

instructions and that you know all applicable legislations regarding 

occupational safety and accident prevention prior to installation and 

putting the component into operation.

The machine builder must carefully select the harmonised standards 

to be complied with as well as other technical specifications for the 

 selection, mounting and integration of the components.

1.3  Explanation of the symbols used

Information, hint, note:

This symbol is used for identifying useful additional information.

Caution:

 Failure to comply with this warning notice could 

lead to failures or malfunctions.

Warning:

 Failure to comply with this warning notice could 

lead to physical injury and/or damage to the machine.

1.4  Appropriate use

The products described in these operating instructions are developed to 

execute safety-related functions as part of an entire plant or machine. It 

is the responsibility of the manufacturer of a machine or plant to ensure 

the correct functionality of the entire machine or plant.

The safety-monitoring module must be exclusively used in accordance 

with the versions listed below or for the applications authorised by the 

manufacturer. Detailed information regarding the range of applications 

can be found in the chapter "Product description".

1.5  General safety instructions

The user must observe the safety instructions in this operating 

 instructions manual, the country-specific installation standards as well 

as all prevailing safety regulations and accident prevention rules.

Further technical information can be found in the Schmersal 

catalogues or in the online catalogue on the Internet:  

www.schmersal.net.

The information contained in this operating instructions manual is 

 provided without liability and is subject to technical modifications.

There are no residual risks, provided that the safety instructions as well 

as the instructions regarding mounting, commissioning, operation and 

maintenance are observed.

Content

1  About this document

1.1  Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.2 

Target group: authorised qualified personnel

. . . . . . . . . . . . . . . . . .1

1.3  Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.4  Appropriate use  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.5  General safety instructions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.6  Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

1.7  Exclusion of liability  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2  Product description

2.1  Ordering code  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.2  Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.3  Destination and use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.4  Technical data  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.5 

Safety classification

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

3  Mounting

3.1  General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

3.2  Dimensions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

4  Electrical connection

4.1  General information for electrical connection. . . . . . . . . . . . . . . . . .3

5  Operating principle and settings

5.1  Operating principle after the operating voltage is switched on  . . . .3

5.2  LED functions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

6  Set-up and maintenance

6.1  Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

6.2  Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

7  Disassembly and disposal

7.1  Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

7.2  Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

8  Appendix

8.1  Wiring examples  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

8.2 

Start configuration

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

8.3 

Sensor configuration

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

8.4 

Actuator configuration

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

8.5 

 Pin configuration (depending on the number of doors)

  . . . . . . . . . .6

9  EU Declaration of conformity

x.000 / 05.2016 / v

.A.   -   101

171507-EN / E / 2016-04-08 / 

AE-Nr

. 5950

EN

Operating instructions. . . . . . . . . . . . .pages 1 to 8

Original

Summary of Contents for AES 2285

Page 1: ... the versions listed below or for the applications authorised by the manufacturer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this operating instructions manual the country specific installation standards as well as all prevailing safety regulations and acci...

Page 2: ... NO contacts of the relays which are wired in series build the enabling contacts 6 signalling outputs signal the position of the corresponding safety guard The entire concept of the control system in which the safety component is integrated must be validated to the relevant standards 2 4 Technical data General data Standards IEC 60204 1 IEC 60947 5 1 IEC 60947 5 3 ISO 13849 1 IEC 61508 BG GS ET 14...

Page 3: ... and the insulation of the feed cables must be designed for the highest voltage which can occur in the device Wiring examples see appendix 5 Operating principle and settings 5 1 Operating principle after the operating voltage is switched on With the guard door closed or the emergency stop command devices unlocked the enabling paths are closed as soon as the start button is pushed During the start ...

Page 4: ...1x year Damaged or defective components must be replaced 7 Disassembly and disposal 7 1 Disassembly The safety monitoring module must be disassembled in a de energised condition only Push up the bottom of the enclosure and hang out slightly tilted forwards 7 2 Disposal The safety monitoring module must be disposed of in an appropriate manner in accordance with the national prescriptions and legisl...

Page 5: ...l of magnetic safety switches according to IEC 60947 5 3 see Fig 5 The control system recognises wire breakage and earth faults in the control circuit Cross wire shorts between the control circuits are detected Category 3 PL d to ISO 13849 1 possible EMERGENCY STOP Door switches Magnetic reed switches S11 S22 S11 S74 S12 S74 S73 S73 S31 S42 S31 S84 S32 S84 S83 S83 S51 S62 S51 S94 S52 S94 S93 S93 A...

Page 6: ...2 S11 S22 NO contacts 1 S73 S74 NO contacts 2 S73 S74 Bridges S31 S32 S42 S51 S52 S62 Number of sensors to be monitored 3 Pin configuration NC contacts 1 S11 S12 NC contacts 2 S11 S22 NC contacts 3 S31 S32 NO contacts 1 S73 S74 NO contacts 2 S73 S74 NO contacts 3 S83 S84 Bridges S31 S42 S51 S52 S62 Number of sensors to be monitored 4 Pin configuration NC contacts 1 S11 S12 NC contacts 2 S11 S22 NC...

Page 7: ...85 Description of the component Safety monitoring module for emergency stop circuits guard door monitoring and magnetic safety switches Relevant Directives Machinery Directive EMC Directive RoHS Directive 2006 42 EC 2014 30 EU 2011 65 EU Applied standards DIN EN 60947 5 3 2014 EN ISO 13849 1 2008 DIN EN ISO 13849 2 2013 Notified body for the prototype test DGUV Test Prüf und Zertifizierungsstelle ...

Page 8: ... A Schmersal GmbH Co KG Möddinghofe 30 D 42279 Wuppertal Postfach 24 02 63 D 42232 Wuppertal Phone 49 0 2 02 64 74 0 Telefax 49 0 2 02 64 74 1 00 E Mail info schmersal com Internet http www schmersal com ...