Installation
50 / 66
EN-US · 30.30.01.01721 · 01 · 09/19
9.3.1 Connecting the Compressed Air and Vacuum
How to Perform Pneumatic Connection for Ejector Variant H
2
1
1
Compressed air connection
2
Vacuum connection
The compressed air connection G3/8" is marked with the number 1 on the ejector.
4
Connect compressed air hose. The max. tightening torque is 6 Nm.
The vacuum connection G3/8" is marked with the number 2 on the ejector.
4
Connect vacuum hose. The max. tightening torque is 6 Nm.
How to Perform Pneumatic Connection for Ejector Variant Q
Compressed air
Vacuum
4
The pneumatic connection is performed by connecting the ejector plug to the Quick Change
adapter.