Description of Functions
EN-US · 30.30.01.01721 · 01 · 09/19
37 / 66
7.11.4 Restricting Access with Extended Device Access Locks [0x005A]
The Extended Device Access Locks gives you the following options:
•
Block all NFC access or restrict it to read-only functions. The NFC lock using the extended device ac-
cess locks parameter has a higher priority than the NFC PIN. That means that this lock also cannot be
bypassed by entering a PIN.
•
Block the use of manual mode.
•
Block the transmission of IO-Link events.
7.12 Resetting to Factory Settings (Clear All) [0x0002]
This function is used to reset the following configurations to their factory settings:
•
The configuration of the ejector
•
The initial setup
•
The production setup profile settings
•
The IO-Link parameter "Application specific tag"
This function is executed using the parameter [
rE5
] in the configuration menu or via IO-Link.
The factory settings for the ejector are listed under
(> See ch. Factory Settings, Page 17)
Data section.
WARNING
By activating/deactivating the product, output signals lead to an action in the pro-
duction process!
Personal injury
4
Avoid possible danger zone.
4
Remain vigilant.
A description of how to reset the ejector to factory settings using the display and operating element fol-
lows:
1. Press the
button for at least three seconds.
2. Use the
or
button to select the parameter [
rE5
].
3. Confirm using the
button.
4. Use
or
to select the required setting parameter [
YE5
].
5. If the menu is locked: Enter a valid PIN code.
6. Confirm using the
button.
ð
The ejector is reset to the factory settings.
The reset to factory settings function does not affect the following elements:
•
The counter readings
•
The zero-point adjustment of the sensors