Schmalz SCPSb-07 Operating Instructions Manual Download Page 1

 

 

Innovative Vacuum-for Automation 

EN 

SCPSb 

Operating instructions 
30.30.01.00488

 

Summary of Contents for SCPSb-07

Page 1: ...Innovative Vacuum for Automation EN SCPSb Operating instructions 30 30 01 00488...

Page 2: ...f Functions 3 8 General functions 3 8 Setting the blow off volume flow 3 8 4 Operating Mode 4 9 Mounting 4 9 Pneumatic connection 4 10 Electrical connection 4 10 5 Maintenance 5 11 General maintenance...

Page 3: ...can be sucked in Compressed air can cause closed containers to explode A vacuum can cause closed containers to implode The ejector may only be operated with a silencer Never look into the exhaust air...

Page 4: ...ntrol components and feed back signals INTENDED USE The ejector is designed to generate a vacuum for gripping and transporting objects when used in conjunction with suction pads Neutral gases in accor...

Page 5: ...that the ejector is disconnected and depressurized and that it cannot be switched on again without authorization Personal injury or damage to the ejector may occur Protect the ejector from damage at...

Page 6: ...events the vacuum from dropping BLOW OFF DEPOSITING THE WORKPIECE The vacuum circuit of the ejector is supplied with compressed air using the blow off pilot valve This ensures that the vacuum drops qu...

Page 7: ...t compressed air during operation Position Description Max tightening torque 1 Pilot valve Suction 0 2 Nm 2 Pilot valve Blow Off 0 2 Nm 3 Blow off valve screw 4 Vacuum connection label 2 V D6 SCPSb 07...

Page 8: ...ed to set the blow off volume flow Turning the screw clockwise reduces the volume flow Turning the screw counterclockwise increases the volume flow The valve screw is equipped with a stop on both side...

Page 9: ...DE MOUNTING SCPSb We recommend using washers when mounting the securing screws Position Description Max tightening torque 1 M4 securing screw 2 Nm 2 Top hat rail clamp for TS35 top hat rail incl plast...

Page 10: ...the vacuum side is too small This leads to both a reduction in suction capacity and increased evacuation times Blow off times are also lengthened Hose lines must be laid without bends or crimps Only...

Page 11: ...ry The same applies to spare parts provided that these are original parts supplied by us We are not liable for any damage resulting from the use of non original spare parts or ac cessories Wearing par...

Page 12: ...sure too low Increase operating pressure observe max limits Internal diameter of hose lines too small See recommended hose diameters Payload cannot be held securely Vacuum level too low Increase opera...

Page 13: ...0V 1 The power supply must comply with the requirements of EN60204 protective extra low voltage 2 Parallel control of the suction and blow off valves 3 Separate control of the suction and blow off va...

Page 14: ...POM Silencer insert Porous PE Seals NBR Lubricants Silicone free Screws Galvanized steel MECHANISCHE PARAMETER Type Nozzle size Max vacuum 1 Suc tion rate 1 Max blow off capacity 1 Air con sumption 1...

Page 15: ...SC HMA LZ SCPSb 6 15 DIMENSIONS SCPSb L L1 L2 L3 L4 B B1 H H1 H2 H3 H4 86 2 102 5 81 4 22 29 5 18 18 6 77 5 97 40 8 47 5 16 5 H5 d d1 d2 d3 X1 X2 Y1 Y2 5 5 4 4 6 6 2 6 36 9 16 12 12...

Page 16: ...SC HMA LZ SCPSb 6 16 PNEUMATIC CIRCUIT DIAGRAMS SCPSb NO SCPSb NC...

Page 17: ...SC HMA LZ SCPSb 7 17 7 CONFORMITY DECLARATION...

Page 18: ...were originally written in German and have been translated into English We reserve the right to make technical changes No responsibility is taken for print errors or other types of errors All informa...

Page 19: ...ds Tel 31 0 74 255 5757 Fax 31 0 74 255 5758 schmalz schmalz nl Poland Tel 48 0 22 46 04970 Fax 48 0 22 87 40062 schmalz schmalz pl Russia Tel 7 495 9671248 Fax 7 495 9671249 schmalz schmalz ru Spain...