![Schmalz SCPS Maintenance Instruction Download Page 8](http://html1.mh-extra.com/html/schmalz/scps/scps_maintenance-instruction_1212885008.webp)
7. Connect the vacuum module (1) and control (2) to-
gether
and tighten the fastening screws with a
tightening torque of 0.7 Nm
.
1
2
1
2
2.6 Changing the Non-Return Valve
1. Loosen the four fastening screws of the ejector
module.
2. Remove the ejector module (1) and remove the
non-return valve or the valve flap and sealing.
1
j
k
3. Insert the new non-return valve or the new valve
flap and sealing in the correct position.
j) Valve flap part no. 10.02.02.04059
k) Sealing frame part no. 10.02.02.04006
k
j
8 / 9
EN-US · 30.30.01.00962 · 01 · 01/22