ð
The pneumatic hoses fit tightly in the plug-in
screw unions.
7.4 Electrical Connection
NOTE
Incorrect power supply
Destruction of the integrated electronics
4
Operate the product using a power supply unit with protected extra-low voltage (PELV).
4
The system must incorporate safe electrical cut-off of the power supply in compliance with
EN60204.
4
Do not connect or disconnect the connector under tension and/or when voltage is applied.
The electrical connection is established directly via the connection plugs of the valves. The connection of the valves
is independent of the polarity.
ü
Provide connection cable (for example, 2x item no.: 21.04.06.00086)
4
Insert the connection cables into the electrical con-
nections (1 and 2) until they click into place.
1
2
14 / 20
EN-US · 30.30.01.02662 · 00 · 02/21