Installation
30 / 52
EN-US · 30.30.01.02553 · 00 · 09/20
7. Wrap the lift tube in adhesive tape (Coroplast)
such that the cover of the lifting unit is fully
sealed. Wind the adhesive tape fully around
the lift tube approx. two times.
6.7 Adjusting the Hovering Position
The working height of the operator handle – without load – can be adjusted to a more ergonomic height
as desired.
NOTE
Operation of the tube lifter without setting the hovering position
Lift tube damage!
4
The hovering position must be set before the initial start of operations.
Setting the Hovering Position
5.3
5.3
ü
No load on the gripper.
4
To adjust the working height, rotate the twist grip (5.3) in the direction of the arrow.
The adjustment range of the hovering position depends on the vacuum generator being used.
Raising the hovering position throttles the flow rate. If the flow rate is reduced too much, por-
ous loads can no longer be lifted.