Technical Data
24 / 94
EN-US · 30.30.01.02237 · 00 · 04/20
Actuator supply voltage U
A
(Pin 2)
Typ. 24 V
Sensor supply voltage L+
(Pin 1)
Typ. 24 V
Supported baud rates
COM 1 (4.8 k bauds)
COM 2 (38.4 k bauds)
COM 3 (230.4 k bauds – max. 4 devices per terminal)
IO-Link specification
The IO-Link ports of the device satisfy the requirements of
the IO-Link specification 1.1.
Max. permitted line length
20 m
Max. permitted output current I_U
A
(PIN 2)
2 A per port
Max. permitted output current I_C/Q
(Pin 4)
100 mA per port
500 mA (per port for WURQ)
Switching threshold (1) C/Q (Pin 4)
C/Q as digital input
Min. 11 V
Switching threshold (0) C/Q (Pin 4)
C/Q as digital input
Max. 11 V
Input current C/Q (Pin 4)
C/Q as digital input
6.2 mA
1)
DI module
Max. permitted supply current U
S
(Pin 1)
Protected against short-cir-
cuits; not overload-proof
200 mA
Specification
IEC 61131-2 type 1, 3 (3 conductors)
Signal voltage (0) DIn
(Pin 2 and 4)
–3 V ... 7 V
Signal voltage (1) DIn (Pin 2 and 4)
11 V ... 36 V
Max. permitted digital input voltage
(Pin 2 and 4)
36 V
Input current I_DIn (Pin 2 and 4)
Max. 2.7 mA
Input filter (Pin 2 and 4)
Typ. 3 ms / max. 4.5 ms
1)
The power supply must correspond to the regulations in accordance with EN60204 (protected extra-low
voltage). In addition, the voltage must be electrically isolated from the sensor supply voltage while taking
the basic insulation into account (in accordance with IEC 61010-1, secondary circuit with maximum 30 V
DC derived from the mains circuit up to 300 V of overvoltage category II).
4.3 Mechanical Data
4.3.1 Performance Data
All data is based on the ejector SCPSt:
Type
Nozzle size
mm
Max. vacuum
1)
%
Suction rate
1)
l/min
Blow-off air
consumption
1)
l/min
Air consump-
tion
1)
l/min
SCPS-07
0.7
85
16
120
22
SCPS-10
1.0
85
36
120
46
SCPS-15
1.5
85
65.5
120
98
SCPS-2-07
0.7
85
37
120
22
SCPS-2-09
0.9
85
49.5
120
40.5
SCPS-2-14
1.4
85
71.5
120
82
1)
at 4 bar