Check the filters at least once a week or in the event of dust accumulation, and blow the filter cartridge clear (from
the inside to the outside).
Replace the filter cartridge if it is very dirty.
9 Troubleshooting
This device should only be installed and maintained by qualified specialist personnel. Check the safety features af-
ter repair or maintenance work is performed.
Fault
Possible cause
Solution
Pump runs, but vacuum does
not reach -0.6 bar.
Filter cover leaking
4
Check the filter cover for leaks.
Blind plug leaking at the reser-
voir
4
Tighten blind plug, replace sealing ring.
Screw unions not tight
4
Check screw unions, retighten and, if
necessary, replace sealing rings.
10 Warranty
This system is guaranteed in accordance with our general terms of trade and delivery. The same applies to spare
parts, provided that these are original parts supplied by us.
We are not liable for any damage resulting from the use of non-original spare parts or accessories.
The exclusive use of original spare parts is a prerequisite for the proper functioning of the system and for the valid-
ity of the warranty.
Wearing parts are not covered by the warranty.
11 Spare and Wearing Parts
Designation
VOL 5
VOL 15
VOL 50
VOL 100
VOL 200
Spare parts
Non-return valve RSV
10.05.05.00002
10.05.05.00003
10.05.05.00004
10.05.05.00006
10.05.05.00008
Vacuum gauge VAM
10.07.02.00003
Wearing parts
Replacement filter car-
tridge FILT-EINS
10.07.01.00014
10.07.01.00017
10.07.01.00018
10.07.01.00020
12 Disposing of the Product
Recover the disassembled parts for recycling or reuse (provided no agreement on return or disposal has been
made).
1. Dispose of the product properly after replacement or decommissioning.
2. Observe the country-specific guidelines and legal obligations for waste prevention and disposal.
13 EC Declaration of Conformity
EC Declaration of Conformity
The manufacturer Schmalz confirms that the vacuum reservoir VOL product described in these operating instruc-
tions fulfills the following applicable EC directives:
2006/42/EC
Machinery Directive
The following harmonized standards were applied:
EN ISO 12100:2010
Safety of Machinery – Basic concepts, general principles for design – risk assessment
EN ISO 4414
Pneumatic fluid power – General rules and safety requirements for systems and
their components
EN-US · 30.30.01.02412 · 00 · 03/20